(Created page with "* Tektronix 067-0077-00 (PDF, OCR)") |
No edit summary |
||
Line 1: | Line 1: | ||
The 067-0077-00 is a square wave calibrator for checking the calibrator circuits in scopes. | |||
It contains a precision voltage divider which it uses to get voltages | |||
in the standard 1-2-5 sequence between 0.2 mV and 100 V. | |||
An internal relay switches between between the divided reference voltage and an external | |||
unknown voltage which is applied to the 067-0077-00. | |||
* [[Media:Tek 067-0077-00.pdf|Tektronix 067-0077-00 (PDF, OCR)]] | * [[Media:Tek 067-0077-00.pdf|Tektronix 067-0077-00 (PDF, OCR)]] |