33,143
edits
No edit summary |
No edit summary |
||
Line 1: | Line 1: | ||
The Tektronix 3S76 is a dual-trace [[sampling oscilloscope|sampling]] plug-in | The Tektronix 3S76 is a dual-trace [[sampling oscilloscope|sampling]] plug-in | ||
for [[560-series scopes]]. The risetime is rated at less than 0.4ns. Each input | for [[560-series scopes]]. The risetime is rated at less than 0.4ns. Each input | ||
has a trigger | has a trigger takeoff transformer and a 55ns coaxial delay line. The trigger source channel is selectable. The sampling bridge is a four-diode design | ||
using beam-lead GaAs diodes, with a [[7586]] nuvistor buffering its output. | |||
The sampling pulse is generated by snap-off diode and a 3cm twisted-pair | |||
clipping line. | |||
* [http://bama.edebris.com/download/tek/3s76/3s76.djvu Tektronix 3S76 Manual (DjVu)] | * [http://bama.edebris.com/download/tek/3s76/3s76.djvu Tektronix 3S76 Manual (DjVu)] | ||
* [http://w140.com/tek_3s76.pdf Tektronix 3S76 Manual (PDF)] |