2335: Difference between revisions

Jump to navigation Jump to search
1,485 bytes added ,  26 May 2019
no edit summary
No edit summary
No edit summary
Line 7: Line 7:
summary=Ruggedized 100 MHz dual trace scope  |
summary=Ruggedized 100 MHz dual trace scope  |
manuals=
manuals=
*[http://exodus.poly.edu/~kurt/manuals/manuals/Tektronix/TEK%202335%20Instruction.pdf Tektronix 2335 Instruction Manual (PDF)]
*[http://exodus.poly.edu/~kurt/manuals/manuals/Tektronix/TEK%202335%20Instruction.pdf Tektronix 2335 Instruction Manual ]] (PDF)
* [[Media:070-4207-00_2235_Operators_Manual.pdf|Tektronix 2335 Operators Manual (PDF]]
* [[Media:070-4207-00_2235_Operators_Manual.pdf| Tektronix 2335 Operators Manual ]] (PDF)
* [[Media:070-4206-00_2235_Service_Manual.pdf|Tektronix 2335 Service Manual (PDF]]
* [[Media:070-4206-00_2235_Service_Manual.pdf| Tektronix 2335 Service Manual ]] (PDF)
* [http://w140.com/Tektronix-2300-Series_Brochure.pdf Tektronix 2300 Series Brochure (PDF)]
* [http://w140.com/Tektronix-2300-Series_Brochure.pdf| Tektronix 2300 Series Brochure ]] (PDF)
* [[Media:070-4115-00.pdf|Tektronix 2335 Instruction Manual (PDF, OCR, bad-OCR)]]
* [[Media:2300_Series_Brochure.pdf| Tektronix 2300 Series Brochure (PDF, OCR)]]
}}


* [[Media:070-4115-00.pdf|Tektronix 2335 Instruction Manual (PDF, OCR, bad-OCR)]]
The Tektronix 2335 is a ruggedized portable dual-channel, 100 MHz analog scope.  An External trigger input on front and External Z-Axis connector at the rear round out its connectivity.  A 150 MHz modification was available.


* [[Media:2300_Series_Brochure.pdf|Tektronix 2300 Series Brochure (PDF, OCR)]]
Vertical controls were by way of calibrated deflection factors on CH 1 or CH 2 inputs through AC, DC, or GND coupling. The vertical mode selections arer CH 1, BOTH, CH 2, ADD, ALT, CHOP (500 kHz), TRIG VIEW, or BW LIMIT (20 MHz).  Horizontal deflection is controlled by either the calibrated A or B Sweep Generators, or Alternate between the two of the A, and B Delayed Sweep.
}}


The '''Tektronix 2335''' is a ruggedized portable dual channel oscilloscope with 100 MHz bandwidth.
Trigger modes may be one of four modes: Single Sweep Reset, P-P Auto-TV Line, Normal, and TV Field.  Trigger sources can be Internal, Line, or External, and can be controlled by amplitude level and slope type.  The Internal signal source(s) is(are) from signals applied to channels 1 or 2, or based on what Vertical Mode selected.
A 150 MHz modification was available.


{{MissingSpecs}}
{{BeginSpecs}}
{{Spec | Bandwidth and Channels| 100 MHz; Bandwidth is at least 90 MHz at 2 mV/div; 2 Channels }}
{{Spec | Deflection Factor| CH 1, 2: 5 mV/div to 5 V/div, all ±2%; Variable control can increase sensitivity to at least 2 mV/div.}}
{{Spec | Input Impedance| 1 MΩ ±2% and 20 pF ±2 pF }}
{{Spec | Maximum Input Voltage| 400 V (DC + peak AC) }}
{{Spec | Sweep Speeds| A Time Base: 0.5 s/div to 50ns/div; B Time Base: 50 ms/div to 50 ns/div; A and B X10 magnifier to 5 ns/div }}
{{Spec | Trigger Source| INT (CH1, 2), LINE, EXT (AC, DC, DC ÷ 10) }}
{{Spec | Probes| Two P6109 150 MHz ×10 probes, BNC connector with a readout pin }}
{{Spec | Power| 40 W max, 90 − 250 VAC, 48 − 440 Hz }}
{{EndSpecs}}