Restoring 1220, 1225 and 1230 keypad: Difference between revisions

Jump to navigation Jump to search
m
No edit summary
Line 10: Line 10:
[[Image:Bounce(4).jpg|thumb|left|250px|(Pic3) Keypad switches]]
[[Image:Bounce(4).jpg|thumb|left|250px|(Pic3) Keypad switches]]
[[Image:Bounce(5).jpg|thumb|right|250px|(Pic4) Keypad switches]]
[[Image:Bounce(5).jpg|thumb|right|250px|(Pic4) Keypad switches]]
* '''WARNING!''' When taking the analyzer apart, users are at there own risk! The inside contains lethal voltages and precaution must be taken.
* '''WARNING!''' When taking the analyzer apart, users are at their own risk! The inside contains lethal voltages and precaution must be taken.
*The switches that the keypad uses are still being manufactured today. They are C&K D6L90F1LFS and the D6L90F2LFS, they are the exact same. The difference being the force required to push the buttons. One takes 1.3 Newtons and the other 2 Newtons (Pic3). The key pad has 26 of them. Replacing them with new ones will fix the excessive bouncing. When de-soldering the switches one has to be careful of burning the PCB and lifting pads because the traces are very small.
*The switches that the keypad uses are still being manufactured today. They are C&K D6L90F1LFS and the D6L90F2LFS, they are the exact same. The difference being the force required to push the buttons. One takes 1.3 Newtons and the other 2 Newtons (Pic3). The keypad has 26 of them. Replacing them with new ones will fix the excessive bouncing. When de-soldering the switches one has to be careful of burning the PCB and lifting pads because the traces are very small.


:→ [[Media:D6L90F1LFS.pdf|Datasheet for D6L90F1LFS and D6L90F2LFS ]]
:→ [[Media:D6L90F1LFS.pdf|Datasheet for D6L90F1LFS and D6L90F2LFS ]]
<div style="clear: both"></div>
<div style="clear: both"></div>
==Conclusion==
==Conclusion==
[[Image:Bounce(3).jpg|thumb|left|250px|(Pic5) Restored keypad.]]  
[[Image:Bounce(3).jpg|thumb|left|250px|(Pic5) Restored keypad.]]  
188

edits

Navigation menu