1,325
edits
(add sidebar & specs) |
mNo edit summary |
||
Line 14: | Line 14: | ||
}} | }} | ||
The P6007 is a medium voltage, 100X, passive probe for use with 1 MΩ input scopes. | |||
It has a BNC connector with no [[readout encoding pin]]. | |||
{{BeginSpecs}} | {{BeginSpecs}} | ||
{{Spec | Bandwidth | ~25 MHz }} | {{Spec | Bandwidth | ~25 MHz }} | ||
{{Spec | Attenuation | 100X ±3% }} | {{Spec | Attenuation | 100X ±3% }} | ||
{{Spec | Maximum Voltage | 1.5 kV DC or 4.2 kV AC p-p }} | {{Spec | Maximum Voltage | 1.5 kV DC or 4.2 kV AC p-p, must be derated at higher frequencies }} | ||
{{Spec | Input Impedance | 10 MΩ plus 2.0 to 2.8 pF, depending on cable length and scope input capacitance }} | {{Spec | Input Impedance | 10 MΩ plus 2.0 to 2.8 pF, depending on cable length and scope input capacitance }} | ||
{{Spec | Compensation Range | 15-55 pF }} | {{Spec | Compensation Range | 15-55 pF }} |
edits