The Tektronix Type 3B4 is a timebase plug-in for 560-series scopes.
The Tektronix Type 3B4 is a timebase plug-in for 560-series scopes. It was introduced in 1964.
It was intended primarily for use
with the 561A, but works fine in other 560-series scopes.  The 3B4 is unusual in having an explicit
"FREE RUN" mode.  In the triggered modes, the tunnel diode-based triggering is rated to work to 20MHz. 
The vertical bandwidth of typical 560-series (non-sampling) scopes is about 10MHz, so 20MHz is adequate.
Triggering is done with a TD3A 4.7mA tunnel diode.  The trigger input is amplified and buffered by a
6DJ8-based differential amplifier driving a common-emitter 2N964 germanium PNP transistor whose
collector current switches the tunnel diode. 