*allowed input voltage range is 5Vpk
*allowed input voltage range is 5Vpk


The 7S14 uses tunnel diode triggering and a two-diode sampler for each channel.
The 7S14 has two triggering modes: triggered and HF-sync.
In triggered mode, the signal passes through two stages of
[[MC1672]] ECL logic gate, and then into the [[155-0109]] trigger chip.
In HF-sync mode, the 7S14 uses a [[BD4]] back diode (0.1mA, 3pF), and inductor, and a
[152-0177-00]] tunnel diode (10mA, 4pF) to form an oscillator that oscillates
somewhere between 16.5MHz and 25MHz. 
 
The sampler used by the 7S14 is a two-diode design. 
Each of the two input channels has its own sampler.


* [http://bama.edebris.com/download/tek/7s14/tek-7s14.pdf Tektronix 7S14 Service Manual (PDF)]