{{ | {{BeginSpecs}} | ||
{{Spec | Bandwidth | 2 GHz }} | |||
{{Spec | Sample rate | 1 channel @ 4 GS/s, 2 channels @ 2 GS/s, 3 or 4 channels @ 1 GS/s }} | |||
{{Spec | Resolution | 8 bit }} | |||
{{Spec | Record length | 50k samples per channel (500k with option 1M, 8M with option 2M) }} | |||
{{Spec | Acquisition modes | sample, envelope, average, high-resolution, peak-detect }} | |||
{{Spec | Display | Color; Zoom }} | |||
{{Spec | Trigger modes | Edge, logic, pulse; Video trigger with option 05 ([[NTSC]], [[SECAM]], [[PAL]], HDTV, and FlexFormat) }} | |||
{{Spec | Storage | 1.44 Mbyte, 3.5 inch, DOS 3.3-or-later floppy disk. NVRAM storage for saving waveforms, hardcopies, and setups. Units with option HD present (requires additional hardware) have a hard disk drive }} | |||
{{Spec | I/O | Full GPIB programmability }} | |||
{{Spec | Hardcopy | Using [[GPIB]], [[RS-232]], or Centronics ports }} | |||
{{EndSpecs}} | |||
==Software== | ==Software== |