Line 12: Line 12:
In a 516, the [[delay line]] directly drives the  
In a 516, the [[delay line]] directly drives the  
vertical deflection plates of the CRT.
vertical deflection plates of the CRT.
The standard CRT is the [[T55]] with P31 [[phosphor]]. 
It has a post-deflection acceleration voltage of +2335V.
The CRT cathode runs at -1675V.
The HV power supply uses three [[5642]] rectifier tubes:
* V822 for the CRT cathode voltage
* V832 for the CRT control grid voltage
* V842 for the post-deflection voltage


* [http://bama.edebris.com/download/tek/516/516.djvu Tektronix 516 Manual (DjVu)]