It provides:
It provides:
* +400V unregulated
* +400V unregulated
* +300V regulated, using one triode of a [6080] as the output tube
* +300V regulated, using one triode of a [[6080]] as the output tube
* +100V regulated, using one triode of a [6080] as the output tube
* +100V regulated, using one triode of a 6080 as the output tube
* -150V regulated, using a [[6AU5]] tube as the output tube
* -150V regulated, using a [[6AU5]] tube as the output tube
The reference for the LV supply is a [[5651]].
The reference for the LV supply is a [[5651]] which produces a -87V reference,
which controls the -150V supply.  The -150V supply is used as the reference for
the +100V and +300V supplies.