* I_R7 (tunnel diode off, input waveform high) = 70mV/(43+50) = 0.75mA.
* I_R7 (tunnel diode off, input waveform high) = 70mV/(43+50) = 0.75mA.


So the tunnel diode gets 11.2mA - 0.75mA = 10.45mA.  This enough to switch
So the tunnel diode gets 11.2mA - 0.75mA = 10.45mA.   
the tunnel diode, even near the high end of its peak current tolerance range.  
This is enough to switch the tunnel diode,  
After the tunnel diode switches to the high voltage state, more current (about 4mA) is diverted
even near the high end of its peak current tolerance range.  
After the tunnel diode switches to the high voltage state,  
more current (about 4mA) is diverted
into the load instead of the tunnel diode.
into the load instead of the tunnel diode.


Line 51: Line 53:
* r_d = 0.025V /  0.006 = 4.2 ohms
* r_d = 0.025V /  0.006 = 4.2 ohms


The ringing current of a parasitic L-C resonator dissipating into the tunnel diode's dynamic resistance
The ringing current of a parasitic L-C resonator dissipating into  
could result in significant time-domain voltage wiggles which would be difficult to distinguish from transient response
the tunnel diode's dynamic resistance could result in significant  
problems in the vertical amplifier of the oscilloscope under test.   
time-domain voltage wiggles which would be difficult to distinguish  
from transient response problems
in the vertical amplifier of the oscilloscope under test.   


* [http://w140.com/tek_067-0681-01.pdf Tektronix 067-0681-01 Datasheet (PDF)]