Line 31: Line 31:
digital counter and a decoder to generate the internal control signals.
digital counter and a decoder to generate the internal control signals.


{| border="1" style="text-align: center;"
|+ Comparison of S-50 with S-52
! scope="col" |
! scope="col" | S-50
! scope="col" | S-52
|-
! scope="col" | Risetime
| under 25ps
| under 25ps
|-
! scope="col" | Amplitide
| 400mV into 50 ohms
| 200mV into 50 ohms
|-
! scope="row" | Output impedance
| varies, not specified || 50 ohms
|-
! scope="row" | Sequencing of internal events
| analog timing circuit
| digital state-machine
|-
! scope="row" | Pretrigger lead time
| 75ns
| 85ns
|-
! scope="row" | Trigger (with pulse) output
| yes, 200mV into 50 ohms
| no
|}