The '''Tektronix 134''' current probe amplifier interfaces a [[P6019]], [[P6020]], [[P6021]] or [[P6022]] current probe to the voltage input of an oscilloscope. It was designed by [[Hans Springer]]. Early versions, up thru S/N 6539, had the switch positions labeled only for the [[P6019]] & [[P6020]]
The '''Tektronix 134''' current probe amplifier interfaces a [[P6019]], [[P6020]], [[P6021]] or [[P6022]] current probe to the voltage input of an oscilloscope. It also had a Volts Only setting of the input attenuator switch that provided a voltage gain of 125 or 50, depending on the position of the probe selector switch. It was designed by [[Hans Springer]]. Early versions, up thru S/N 6539, had the switch positions labeled only for the [[P6019]] & [[P6020]] probes but these early versions are still compatible with the later [[P6021]] & [[P6022]] probes introduced in 1969.
probes but these early versions are still compatible with the later [[P6021]] & [[P6022]] probes introduced in 1969.


Each 134 came with its own separate, dedicated power supply using the same Tektronix proprietary coaxial connector as that used in the Type [[131]]s and its [[015-027 | power supplies ]]. For more information on the power supplies for the Type 134 see the separate Type [[015-0058-01 | 134 Power Supplies ]] page.
Each 134 came with its own separate, dedicated power supply using the same Tektronix proprietary coaxial connector as that used in the Type [[131]]s and its [[015-027 | power supplies ]]. For more information on the power supplies for the Type 134 see the separate Type [[015-0058-01 | 134 Power Supplies ]] page.


{{BeginSpecs}}
{{BeginSpecs}}
{{Spec | Current range | 1 mA/Div to 1 A/Div, 1−2−5 (scope at 50 mV/Div) }}
{{Spec | Current Ranges | 1 mA/Div to 1 A/Div, 1−2−5 (scope at 50 mV/Div) }}
{{Spec | Gain | 125 in P6019/P6021 switch position }}
{{Spec | Voltage Gain | 125 in P6019/P6021 switch position }}
{{Spec | Gain | 50 for P6020/P6022 switch position }}
{{Spec | Voltage Gain | 50 in P6020/P6022 switch position }}
{{Spec | Bandwidth | 10 Hz to 30 MHz in P6019/P6021 x120 mode }}
{{Spec | Bandwidth | 10 Hz to 30 MHz in P6019/P6021 x120 mode }}
{{Spec | Bandwidth | 8 Hz to 54 MHz in P6020/P6022 x50 mode }}
{{Spec | Bandwidth | 8 Hz to 54 MHz in P6020/P6022 x50 mode }}