! Type 134 <br | ! P6019 + <br>Type 134 | ||
! Type 134 <br | ! P6019 + <br>Passive<br>Termination | ||
! Type 134 <br | ! P6021 + <br>Type 134 | ||
! Type 134 <br | ! P6021 + <br>Passive<br>Termination | ||
! P6020 + <br>Type 134 | |||
! P6020 + <br>Passive<br>Termination | |||
! P6022 + <br>Type 134 | |||
! P6022 + <br>Passive<br>Termination | |||
|- | |- | ||
! Low Frequency -3 dB | ! Low Frequency -3 dB | ||
|align=right| ≤12 Hz | |align=right|≤12 Hz | ||
|align=right| ≤12 Hz | |align=right|≤120 Hz<br>≤450 Hz | ||
|align=right| ≤100 Hz | |align=right|≤12 Hz | ||
|align=right| ≤100 Hz | |align=right|≤120 Hz<br>≤450 Hz | ||
|align=right|≤100 Hz | |||
|align=right|≤935 Hz<br>≤8500 kHz | |||
|align=right|≤100 Hz | |||
|align=right|≤935 Hz<br>≤8500 kHz | |||
|- | |- | ||
! High Frequency -3dB | ! High Frequency -3dB | ||
|align=right| ≥40 MHz | |align=right| ≥40 MHz | ||
|align=right| ≥60 MHz | |||
|align=right| ≥36 MHz* | |align=right| ≥36 MHz* | ||
|align=right| ≥40 MHz | |||
|align=right| ≥70 MHz | |align=right| ≥70 MHz | ||
|align=right| | |align=right| ≥200 MHz | ||
|align=right| ≥70 MHz* | |||
|align=right| ≥200 MHz | |||
|- | |- | ||
! Max. Continuous Current | ! Max. Continuous Current | ||
|align=right| 15 A<sub>p-p</sub> | |align=right| 15 A<sub>p-p</sub> | ||
|align=right| 15 A<sub>p-p</sub> | |align=right| 15 A<sub>p-p</sub> | ||
|align=right| 15 A<sub>p-p</sub> | |||
|align=right| 15 A<sub>p-p</sub> | |||
|align=right| 6 A<sub>p-p</sub> | |||
|align=right| 6 A<sub>p-p</sub> | |||
|align=right| 6 A<sub>p-p</sub> | |align=right| 6 A<sub>p-p</sub> | ||
|align=right| 6 A<sub>p-p</sub> | |align=right| 6 A<sub>p-p</sub> | ||
Line 58: | Line 74: | ||
|} | |} | ||
* These figures take into account the effects of a 100 MHz oscilloscope. There appears to be little or no electrical difference between the early and late families of the Tektronix current probes. | * These figures take into account the effects of a 100 MHz oscilloscope. There appears to be little or no electrical difference between the early and late families of the Tektronix current probes. | ||
Note that in every case, the passive termination is better for high frequency response, while the Type 134 improves the low frequency response. | |||