544: Difference between revisions
No edit summary |
No edit summary |
||
(22 intermediate revisions by 4 users not shown) | |||
Line 1: | Line 1: | ||
The Type 544 is a | {{Oscilloscope Sidebar| | ||
It has one timebase | title=Tektronix 544| | ||
image=T tek scope 544 front.jpg| | |||
caption=Tektronix 544, front view (with [[1A1]] plug-in) | | |||
To make horizontal magnification usable, the 544 has a | introduced=1964 | | ||
vernier horizontal position control in addition to the | discontinued=1973 | | ||
regular horizontal position control. | summary=50 MHz oscilloscope| | ||
The fastest calibrated sweep is | manuals= | ||
Some magnification modes provide | * [http://bama.edebris.com/download/tek/544/544.djvu Tektronix 544 Manual (DjVu)] | ||
sweeps faster than | * [http://w140.com/tek_544.pdf Tektronix 544 Manual (PDF)] | ||
but in those modes the horizontal scale is not calibrated, | <!-- * [[Media:Tek 547 544 546 technical instruction and training.pdf|Tektronix 547, 546, and 544 Technical Instruction and Training (PDF, needs OCR)]] --> | ||
and a lamp on the front panel lights up | * [http://w140.com/Hi-speed_recorder.pdf General Electric Report from 1968 Discussing Tek 544 Mod 108G (PDF)] | ||
to remind the operator of that. | |||
* [[Media:070-418.pdf|Tektronix 544 Manual (PDF, OCR, bad-OCR)]] | |||
* [[Media:Tek_547_544_546_tech_instr_and_training.pdf|Tektronix 547, 546, and 544 Technical Instruction and Training (PDF, OCR)]] | |||
* [[Media:GE_report_1968.pdf|General Electric Report from 1968 Discussing Tek 544 Mod 108G (PDF, OCR, bad-OCR)]] | |||
* [[Media:Tek 544 fcp dec 1968.pdf|Tektronix 544 Factory Calibration Procedure, December 1968 (PDF, needs OCR)]] | |||
}} | |||
The '''Tektronix Type 544''' is a 50 MHz scope [[introduced in 1964]]. | |||
It has one timebase with several horizontal magnifier modes (×2, ×5, ×10, ×20, ×50, and ×100). | |||
To make horizontal magnification usable, the 544 has a vernier horizontal position control in addition to the regular horizontal position control. | |||
The fastest calibrated sweep is 10 ns/div. | |||
Some magnification modes provide sweeps faster than 10 ns/div, but in those modes the horizontal scale is not calibrated, and a lamp on the front panel lights up to remind the operator of that. | |||
The 544 (at least the early ones) uses the same [[tunnel diodes|tunnel diode]] triggering circuit | |||
as is used in early [[547]] (tunnel diode in the collector load of a PNP differential amplifier). | |||
There is also a rackmount version, the RM544. | |||
A factory modification, MOD 108G, was available that increased the accelerating voltage to 24 kV. | |||
The 1968 catalog lists an RM544 Mod 720 which has a direct-access plug-in and has 1 ns risetime (equiv. 350 MHz). | |||
The 544 | The vertical amplifier and low voltage power supply of the 544 are the same as those of the [[546]] and [[547]]. | ||
[[ | The 544 uses the [[154-0478-00]] CRT which is also used by the [[543|543B]], [[545|545B]], [[546]], and [[547]]. | ||
The project lead for the development of the Tektronix 544, [[546]], and [[547]] was [[Bob Rullman]]. | |||
was | |||
{{MissingSpecs}} | |||
==Pictures== | |||
<gallery> | <gallery> | ||
Tek 544 cl.jpg | |||
T tek scope 544 front.jpg|544 Front view | |||
T tek scope 544 left.jpg|544 Left Internal | |||
T tek scope 544 right.jpg|544 Right Internal | |||
Tek 544.jpg | '''544''' with [[G|Type G]] plug-in, front view | |||
Tek rm544.jpg | '''RM544''' with [[1A1]] plug-in, front view | |||
</gallery> | </gallery> | ||
[[Category:500 series scopes]] |
Revision as of 08:33, 2 June 2019
The Tektronix Type 544 is a 50 MHz scope introduced in 1964.
It has one timebase with several horizontal magnifier modes (×2, ×5, ×10, ×20, ×50, and ×100). To make horizontal magnification usable, the 544 has a vernier horizontal position control in addition to the regular horizontal position control. The fastest calibrated sweep is 10 ns/div. Some magnification modes provide sweeps faster than 10 ns/div, but in those modes the horizontal scale is not calibrated, and a lamp on the front panel lights up to remind the operator of that.
The 544 (at least the early ones) uses the same tunnel diode triggering circuit as is used in early 547 (tunnel diode in the collector load of a PNP differential amplifier).
There is also a rackmount version, the RM544.
A factory modification, MOD 108G, was available that increased the accelerating voltage to 24 kV. The 1968 catalog lists an RM544 Mod 720 which has a direct-access plug-in and has 1 ns risetime (equiv. 350 MHz).
The vertical amplifier and low voltage power supply of the 544 are the same as those of the 546 and 547. The 544 uses the 154-0478-00 CRT which is also used by the 543B, 545B, 546, and 547.
The project lead for the development of the Tektronix 544, 546, and 547 was Bob Rullman.
Key Specifications
- please add