D: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 8: Line 8:
series=500-series scopes |
series=500-series scopes |
manuals=
manuals=
* [http://w140.com/mmm/tek-d.pdf Tektronix Type D Manual (PDF)]
* [[Media:070-228.pdf|Tektronix Type D Manual]] (PDF, OCR, bad-OCR)
<!-- * [http://w140.com/tek_fcp/tek_type_d_factory_cal_proc.pdf Cal procedure] -->
* [http://bama.edebris.com/manuals/tek/d/ Type D manual @ BAMA]
* [[Media:070-228.pdf|Tektronix Type D Manual (PDF, OCR, bad-OCR)]]
* [[Media:tek_type_d_fcp.pdf|Tektronix Type D Factory Calibration Procedure (PDF, OCR)]]
* [[Media:tek_type_d_fcp.pdf|Tektronix Type D Factory Calibration Procedure (PDF, OCR)]]
* [[Media:Tek type d cal outline.pdf|Tektronix Type D Calibration Outline (PDF, OCR)]]
* [[Media:Tek type d cal outline.pdf|Tektronix Type D Calibration Outline (PDF, OCR)]]
<!-- * [http://w140.com/tek_fcp/tek_type_d_factory_cal_proc.pdf Cal procedure]
* [http://bama.edebris.com/manuals/tek/d/ Type D manual @ BAMA] -->
}}
}}
The '''Tektronix Type D''' is a differential amplifier plug-in for [[500-series scopes]].
The '''Tektronix Type D''' is a differential amplifier plug-in for [[500-series scopes]].


Line 23: Line 21:
This scheme would be reprised in Type [[W]].
This scheme would be reprised in Type [[W]].


It displays the difference between two input signals, with a common-mode rejection ratio of 10,000.  It has
It displays the difference between two input signals, with a common-mode rejection ratio of 10,000.   
six tubes, on a shock-mounted subchassis to avoid microphonics.
It has six tubes, on a shock-mounted subchassis to avoid microphonics.


Along with Types [[A]], [[B]], and [[C]], Type D was introduced with the [[531]] and [[535]] in [[introduced in 1954|1954]].
Along with Types [[A]], [[B]], and [[C]], Type D was introduced with the [[531]] and [[535]] in [[introduced in 1954|1954]].
Line 39: Line 37:
==Internals==
==Internals==
Instruments below serial number 3462 used a pair of [[5814]] tubes at the input; later production used [[12AU7]]'s.
Instruments below serial number 3462 used a pair of [[5814]] tubes at the input; later production used [[12AU7]]'s.
These two tube types have different heater currents, and because the heaters are
These two tube types have different heater currents, and because the heaters are series-wired, you cannot switch from one type to the other without circuit modification.
series-wired, you cannot switch from one type to the other without circuit modification.


{{BeginSpecs}}
{{BeginSpecs}}

Revision as of 15:20, 18 August 2021

Tektronix Type D
Differential amplifier
D front view

Compatible with 500-series scopes

Produced from 1954 to 1969

Manuals
Manuals – Specifications – Links – Pictures

The Tektronix Type D is a differential amplifier plug-in for 500-series scopes.

Type D was the most sensitive plug-in of the original four. The bandwidth depends on the gain, ranging from 2 MHz at 50 mV/div to 300 kHz at 1 mV/div. There are two axes of sensitivity setting: a decade attenuator in front of a gain switch. This scheme would be reprised in Type W.

It displays the difference between two input signals, with a common-mode rejection ratio of 10,000. It has six tubes, on a shock-mounted subchassis to avoid microphonics.

Along with Types A, B, and C, Type D was introduced with the 531 and 535 in 1954.

At the time it was called Type 53D. It was briefly renamed 53D/54D in 1955 with the introduction of the 541 and 545. This quickly changed to 53/54D, and finally shortened to just "D" in 1959 with the introduction of the 5xxA scopes. Its final year in the catalog was 1968; it had been superseded by Type 1A7 and 1A6.

K, L, and T are tied for longest production life, at 16 years. B, D, and G are next at 15 years.

Lavoie Laboratories produced an unauthorized clone, the Lavoie LA-265-D.

Internals

Instruments below serial number 3462 used a pair of 5814 tubes at the input; later production used 12AU7's. These two tube types have different heater currents, and because the heaters are series-wired, you cannot switch from one type to the other without circuit modification.

Key Specifications

Deflection 1 mV/Div to 50 V/Div in 1–2–5-10-20-50 sequence and 1-10-100-1000 sequence
Input impedance 1 MΩ // 47 pF (either input)
Bandwidth 2 MHz with MV/CM MULTIPLIER set to 50; 300kHz with MV/CM MULTIPLIER set to 1
CMRR 10000:1 with MILLIVOLTS/CM set to 1, 1000:1 otherwise
Signal ranges
Range Common mode dynamic range*
MILLIVOLTS/CM = 1 ±2.5 V
MILLIVOLTS/CM = 10 ±25 V
MILLIVOLTS/CM = 100 ±250 V
MILLIVOLTS/CM = 1000 ±500 V
  • In practice, Type D behaves well up to about +/-15V if the CM signal is either a brief excursion or a constant. If the CM varies slowly, DC shift in the input tubes will degrade CMRR.

Pictures