Page values for "P6106"

Jump to navigation Jump to search

"_pageData" values

1 row is stored for this page
FieldField typeValue
_creationDateDatetime2015-04-30 6:05:35 PM
_modificationDateDatetime2024-03-27 8:20:13 AM
_categoriesList of String, delimiter: |1 MΩ Oscilloscope probes Introduced in 1977 Miniature modular probes
_isRedirectBooleanNo
_pageIDInteger6,098
_pageNamePageP6106
_pageTitleString

P6106

_pageNamespaceInteger0

"Products" values

1 row is stored for this page
FieldField typeValue
ManufacturerPageTektronix
ModelStringP6106
ClassStringProbe
DescriptionWikitext string

Passive 250 MHz, ×10 probe

SeriesPage1 MΩ scope inputs
IntroducedText1977
DesignersList of Page, delimiter: ;
DiscontinuedText(?)

"Specifications" values

5 rows are stored for this page
FieldField typeValue
ParameterStringAttenuation
ValueWikitext

10 × ±3% with scope input at 1 MΩ ±2%

FieldField typeValue
ParameterStringCompensation range
ValueWikitext

15 pF to 24 pF

FieldField typeValue
ParameterStringBandwidth
ValueWikitext

>250 MHz (>150 MHz for 3 meter cable). Using the 1 meter probe with a scope having at least 325 MHz bandwidth results in a system bandwidth of 300 MHz typ.

FieldField typeValue
ParameterStringInput capacitance
ValueWikitext

10.5 pF (1 m), 13.0 pF (2 m), 15.5 pF (3 m)

FieldField typeValue
ParameterStringMaximum input voltage
ValueWikitext

500 V (DC + peak AC) with derating