Page values for "2337"

"_pageData" values

1 row is stored for this page
FieldField typeValue
_creationDateDatetime2010-08-05 4:46:33 PM
_modificationDateDatetime2023-10-27 10:03:25 PM
_categoriesList of String, delimiter: |2300 series scopes Introduced in 1982 Manual needed
_isRedirectBooleanNo
_pageIDInteger830
_pageNamePage2337
_pageTitleString

2337

_pageNamespaceInteger0

"Products" values

1 row is stored for this page
FieldField typeValue
ManufacturerPageTektronix
ModelString2337
ClassStringOscilloscope
DescriptionWikitext string

Ruggedized 100 MHz dual trace scope

SeriesPage2000-series scopes
IntroducedText1982
DesignersList of Page, delimiter: ;
DiscontinuedText1991

"Specifications" values

8 rows are stored for this page
FieldField typeValue
ParameterStringBandwidth
ValueWikitext

100 MHz (≥88 MHz at 2 mV/Div)

FieldField typeValue
ParameterStringDeflection
ValueWikitext

CH1, CH2: 5 mV/Div to 5 V/Div, 1–2–5; all ±3%; Variable control can increase sensitivity to at least 2 mV/Div

FieldField typeValue
ParameterStringInput Impedance
ValueWikitext

1 MΩ ±2% // 20 pF ±10%

FieldField typeValue
ParameterStringMaximum Input
ValueWikitext

400 V (DC + peak AC) or 500 V (p-p ac at ≤ 1 kHz)

FieldField typeValue
ParameterStringSweep
ValueWikitext

A Time Base 0.5 s/div to 50 ns/div; B Time Base 50 ms/div to 50 ns/div; A and B ×10 magnifier extends max sweep to 5 ns/div

FieldField typeValue
ParameterStringTrigger Source
ValueWikitext

VERT MODE, CH1, CH2, LINE, EXT, EXT ÷ 10)

FieldField typeValue
ParameterStringProbes
ValueWikitext

Two P6108A 100 MHz ×10 probes, BNC connector with a readout pin; One P6101A ×1 probe

FieldField typeValue
ParameterStringPower
ValueWikitext

90 − 250 VAC, 48 − 440 Hz, 60 W max