Page values for "DC504A"

"_pageData" values

1 row is stored for this page
FieldField typeValue
_creationDateDatetime2014-06-16 6:41:46 PM
_modificationDateDatetime2024-10-31 12:47:23 PM
_categoriesList of String, delimiter: |
_isRedirectBooleanNo
_pageIDInteger4,001
_pageNamePageDC504A
_pageTitleString

DC504A

_pageNamespaceInteger0

"Products" values

1 row is stored for this page
FieldField typeValue
ManufacturerPageTektronix
ModelStringDC504A
ClassStringPlug-in
DescriptionWikitext string

100 MHz, 6-digit frequency counter

SeriesPageTM500 system
IntroducedText1984
DesignersList of Page, delimiter: ;
DiscontinuedText1993

"Specifications" values

11 rows are stored for this page
FieldField typeValue
ParameterStringResolution
ValueWikitext

6 digits

FieldField typeValue
ParameterStringFrequency Range
ValueWikitext

DC (AC coupled: 10 Hz) to 100 MHz (rear interface 50 MHz)

FieldField typeValue
ParameterStringSensitivity
ValueWikitext

30 mVRMS sine wave to 100 MHz, 85 mVp-p pulse ≥5 ns

FieldField typeValue
ParameterStringInput impedance
ValueWikitext

1 MΩ // 25 pF (rear interface 50 Ω)

FieldField typeValue
ParameterStringGate time
ValueWikitext

10 ms to 10 s in decade steps (autoranging 10 ms to 1 s)

FieldField typeValue
ParameterStringTrigger Level Range
ValueWikitext

±2 V × attenuator setting

FieldField typeValue
ParameterStringTotalize mode
ValueWikitext

1–999999 counts up to 10 MHz

FieldField typeValue
ParameterStringFrequency Resolution
ValueWikitext

kHz ranges: 0.1 Hz; 1 Hz and 10 Hz (7 digit resolution possible in overflow kHz position); MHz ranges: 100 Hz, 1 kHz (9 digit resolution possible in overflow kHz position)

FieldField typeValue
ParameterStringPeriod resolution
ValueWikitext

ms ranges: 1 µs, 10 µs; s ranges: 10 ms, 1 ms, 0.1 ms

FieldField typeValue
ParameterStringDisplay Time
ValueWikitext

Variable ~0.1 s ... ~10 s and HOLD mode

FieldField typeValue
ParameterStringTime Base
ValueWikitext

10 MHz, ±1×10-7, ±5 ppm from 0°C to +50°C, ±1×10-6 per year, Adjustable to within 5×10-8