_categories | List of String, delimiter: | | 1 MΩ Oscilloscope probes • 6-32 probes • Introduced in (?) |
_isRedirect | Boolean | No |
_pageID | Integer | 7,442 |
_pageName | Page | P6007 |
_pageTitle | String | P6007 |
_pageNamespace | Integer | 0 |
"Products" values
1 row is stored for this pageField | Field type | Value |
---|---|---|
Manufacturer | Page | Tektronix |
Model | String | P6007 |
Class | String | Probe |
Description | Wikitext string | 25 MHz, 100×, HV, Passive Probe |
Series | Page | 1 MΩ scope inputs |
Introduced | Text | (?) |
Designers | List of Page, delimiter: ; | |
Discontinued | Text | (?) |
"Specifications" values
5 rows are stored for this pageField | Field type | Value |
---|---|---|
Parameter | String | Bandwidth |
Value | Wikitext | 25 MHz |
Field | Field type | Value |
---|---|---|
Parameter | String | Attenuation |
Value | Wikitext | 100× ±3% |
Field | Field type | Value |
---|---|---|
Parameter | String | Maximum input |
Value | Wikitext | 1.5 kV DC or 4.2 kV AC p-p, must be derated at higher frequencies |
Field | Field type | Value |
---|---|---|
Parameter | String | Input impedance |
Value | Wikitext | 10 MΩ plus 2.0 to 2.8 pF, depending on cable length and scope input capacitance |
Field | Field type | Value |
---|---|---|
Parameter | String | Compensation range |
Value | Wikitext | 15-55 pF |