1 row is stored for this page
Field | Field type | Value |
---|
_creationDate | Datetime | 2011-02-06 6:48:50 PM |
_modificationDate | Datetime | 2023-10-27 9:37:08 PM |
_categories | List of String, delimiter: | | Introduced in 1976 • T900 series scopes |
_isRedirect | Boolean | No |
_pageID | Integer | 1,272 |
_pageName | Page | T932 |
_pageTitle | String | T932
|
_pageNamespace | Integer | 0 |
1 row is stored for this page
Field | Field type | Value |
---|
Manufacturer | Page | Tektronix |
Model | String | T932 |
Class | String | Oscilloscope |
Description | Wikitext string | 35 MHz dual channel analog scope
|
Series | Page | T900-series scopes |
Introduced | Text | 1976 |
Designers | List of Page, delimiter: ; | {{{designers}}} |
Discontinued | Text | 1981 |
9 rows are stored for this page
Field | Field type | Value |
---|
Parameter | String | Bandwidth |
Value | Wikitext | 35 MHz
|
Field | Field type | Value |
---|
Parameter | String | Deflection |
Value | Wikitext | 2 mV/Div to 10 V/Div, 1–2–5; 2.5× variable
|
Field | Field type | Value |
---|
Parameter | String | Sweep |
Value | Wikitext | 100 ns/Div to 500 ms/Div, 1–2–5; variable magnifier up to ×10 (i.e. down to 10 ns/Div)
|
Field | Field type | Value |
---|
Parameter | String | X-Y Mode |
Value | Wikitext | X input 1 MΩ // 30 pF, 0.1 or 1 V/Div, 2 MHz
|
Field | Field type | Value |
---|
Parameter | String | CRT |
Value | Wikitext | 154-0729-00, 8 × 10 cm², P31 phosphor, 12.4 kV acceleration
|
Field | Field type | Value |
---|
Parameter | String | Power |
Value | Wikitext | 90-110 V, 108-132 V, 198-242 V, 216-250 V, 50-60 Hz, <35 W
|
Field | Field type | Value |
---|
Parameter | String | Dimensions |
Value | Wikitext | 18 × 24.4 × 47.5 cm³ (W/H/L)
|
Field | Field type | Value |
---|
Parameter | String | Weight |
Value | Wikitext | 6.8 kg (15 lbs)
|
Field | Field type | Value |
---|
Parameter | String | Features |
Value | Wikitext | - TV Sync
- Z input (max. ±30 V into 10 kΩ, 5 MHz)
- Calibrator (1 kHz, 0.5 V)
|