Page values for "191"
Jump to navigation
Jump to search
"_pageData" values
1 row is stored for this pageField | Field type | Value |
---|---|---|
_creationDate | Datetime | 2010-05-01 7:27:08 PM |
_modificationDate | Datetime | 2024-10-16 12:47:21 PM |
_categories | List of String, delimiter: | | GR874 • Introduced in 1966 • Signal generators |
_isRedirect | Boolean | No |
_pageID | Integer | 427 |
_pageName | Page | 191 |
_pageTitle | String | 191 |
_pageNamespace | Integer | 0 |
"Products" values
1 row is stored for this pageField | Field type | Value |
---|---|---|
Manufacturer | Page | Tektronix |
Model | String | 191 |
Class | String | Signal generator |
Description | Wikitext string | Constant-amplitude signal generator |
Series | Page | |
Introduced | Text | 1966 |
Designers | List of Page, delimiter: ; | John Mulvey |
Discontinued | Text | (?) |
"Specifications" values
7 rows are stored for this pageField | Field type | Value |
---|---|---|
Parameter | String | Output impedance |
Value | Wikitext | 50 Ω |
Field | Field type | Value |
---|---|---|
Parameter | String | Amplitude range |
Value | Wikitext | 5–50 mV, 50-500 mV, 0.5-5 Vp-p |
Field | Field type | Value |
---|---|---|
Parameter | String | Amplitude accuracy |
Value | Wikitext | At 50 kHz into a 50 Ω load: ±3% for 0.5–5 V range; ±4% for 50–500 mV range; ±5% for 5–50 mV range |
Field | Field type | Value |
---|---|---|
Parameter | String | Amplitude regulation |
Value | Wikitext | ±3% for 5 mV to 5.5 V into 50 Ω at 50 KHz; +3%/-5% for 5 mV and 55 mV ranges or frequency >42 MHz |
Field | Field type | Value |
---|---|---|
Parameter | String | Frequency range |
Value | Wikitext | 350 kHz – 100 MHz |
Field | Field type | Value |
---|---|---|
Parameter | String | Frequency accuracy |
Value | Wikitext | Within ±2% of the selected frequency when the output is terminated with 50 Ω |
Field | Field type | Value |
---|---|---|
Parameter | String | Harmonic content |
Value | Wikitext | Typically less than 5% |