Page values for "DC504"
Jump to navigation
Jump to search
"_pageData" values
1 row is stored for this pageField | Field type | Value |
---|---|---|
_creationDate | Datetime | 2011-10-24 3:13:33 AM |
_modificationDate | Datetime | 2024-10-06 1:07:04 PM |
_categories | List of String, delimiter: | | |
_isRedirect | Boolean | No |
_pageID | Integer | 1,919 |
_pageName | Page | DC504 |
_pageTitle | String | DC504 |
_pageNamespace | Integer | 0 |
"Products" values
1 row is stored for this pageField | Field type | Value |
---|---|---|
Manufacturer | Page | Tektronix |
Model | String | DC504 |
Class | String | Plug-in |
Description | Wikitext string | 80 MHz, 5-digit frequency counter |
Series | Page | TM500 system |
Introduced | Text | 1975 |
Designers | List of Page, delimiter: ; | |
Discontinued | Text | 1983 |
"Specifications" values
9 rows are stored for this pageField | Field type | Value |
---|---|---|
Parameter | String | Frequency Range |
Value | Wikitext | DC (AC coupled: 10 Hz) to at least 80 MHz |
Field | Field type | Value |
---|---|---|
Parameter | String | Sensitivity |
Value | Wikitext | 20 mVRMS sine wave below 15 MHz, 35 mVRMS to 50 MHz, derated down to 175 mVRMS at 80 MHz |
Field | Field type | Value |
---|---|---|
Parameter | String | Input impedance |
Value | Wikitext | 1 MΩ // 20 pF |
Field | Field type | Value |
---|---|---|
Parameter | String | Trigger Level Range |
Value | Wikitext | −1.5 V to +1.5 V |
Field | Field type | Value |
---|---|---|
Parameter | String | Frequency Resolution |
Value | Wikitext | kHz ranges: 0.1 Hz; 1 Hz and 10 Hz (7 digit resolution possible in overflow kHz position); MHz ranges: 100 Hz, 1 kHz (9 digit resolution possible in overflow kHz position) |
Field | Field type | Value |
---|---|---|
Parameter | String | Period resolution |
Value | Wikitext | ms ranges: 1 µs, 10 µs; s ranges: 10 ms, 1 ms, 0.1 ms |
Field | Field type | Value |
---|---|---|
Parameter | String | Display Time |
Value | Wikitext | Variable ~0.1 s ... ~10 s and HOLD mode |
Field | Field type | Value |
---|---|---|
Parameter | String | Standard Time Base |
Value | Wikitext | 1 MHz, ±1×10-5 from 0°C to +50°C, ±1×10-5 per month, Adjustable to within 1×10-7 |
Field | Field type | Value |
---|---|---|
Parameter | String | Opt. 1 Time Base |
Value | Wikitext | 5 MHz, ±1×10-7 from 0°C to +50°C, ±1×10-7 per month, Adjustable to within 1×10-9 |