FieldField typeValue
ParameterStringRise time
ValueWikitext

3.5 ns in combination with Type 80

FieldField typeValue
ParameterStringBandwidth
ValueWikitext

DC to 100 MHz (from 25 Ω source) in combination with Type 80

FieldField typeValue
ParameterStringDeflection
ValueWikitext

0.1 V/Div (fixed) without optional attenuators; 0.2/0.4/0.5/1/2/5/10/20/50/100/200/500/1000 V/Div with attenuators

FieldField typeValue
ParameterStringInput impedance
ValueWikitext

100 kΩ // <14 pF (including capacitive coupler, without attenuators)

FieldField typeValue
ParameterStringInput voltage
ValueWikitext

max. 150 VDC in AC position; max. 600 VDC with optional capacitive coupler; max. 100 VDC when DC coupled (without optional attenuators)