Page values for "SG504"
Jump to navigation
Jump to search
"_pageData" values
1 row is stored for this pageField | Field type | Value |
---|---|---|
_creationDate | Datetime | 2012-02-21 5:06:56 AM |
_modificationDate | Datetime | 2024-02-19 9:25:34 AM |
_categories | List of String, delimiter: | | Introduced in 1974 • TM500 signal generator plugins |
_isRedirect | Boolean | No |
_pageID | Integer | 2,216 |
_pageName | Page | SG504 |
_pageTitle | String | SG504 |
_pageNamespace | Integer | 0 |
"Products" values
1 row is stored for this pageField | Field type | Value |
---|---|---|
Manufacturer | Page | Tektronix |
Model | String | SG504 |
Class | String | Plug-in |
Description | Wikitext string | leveled sinewave generator |
Series | Page | TM500 system |
Introduced | Text | 1974 |
Designers | List of Page, delimiter: ; | |
Discontinued | Text | 1993 |
"Specifications" values
4 rows are stored for this pageField | Field type | Value |
---|---|---|
Parameter | String | Frequency range |
Value | Wikitext | 50 kHz or 6 MHz (Ref), 245 MHz to 550 MHz (Lo), 495 MHz to 1050 MHz (Hi) |
Field | Field type | Value |
---|---|---|
Parameter | String | Output amplitude |
Value | Wikitext | 0.5 Vp-p to at least 4 Vp-p, flat to within ±4% |
Field | Field type | Value |
---|---|---|
Parameter | String | Monitor output |
Value | Wikitext | 0.3 Vp-p into 50 Ω |
Field | Field type | Value |
---|---|---|
Parameter | String | FM input |
Value | Wikitext | ±9 V into 50 kΩ (DC to 100 kHz) produces ±0.05% to ±0.4% deviation depending on frequency |