The Tektronix P6042 is a DC to 50 MHz current probe introduced in 1967.
The sensor contains a current transformer for HF and a hall effect sensor for LF/DC components. The amplifier combines DC/LF and HF signals.
The AM503 is a redesign of the P6042.
Key Specifications
Bandwidth | DC to 50 MHz (-3 dB) |
---|---|
Rise time | 7 ns |
Ranges | 1 mA/Div to 1 A/Div (1-2-5) |
Output | to 50 Ω scope input at 50 mV/Div |
Maximum input | 10 A DC+peak AC in 5 mA to 1 A ranges, 0.5 A in 1 mA and 2 mA ranges |
Power | 90-136 or 180-272 V, 20 W |