The Tektronix 067-0596-00 Chopped Voltage Reference Calibration Fixture is a signal generator
The '''Tektronix 067-0596-00 Chopped Voltage Reference Calibration Fixture''' is a signal generator
that produces an approximately square waveform that alternates between two precisely  
that produces an approximately square waveform that alternates between two precisely  
controlled voltages, "V1" and "V2".  The unit consists of three subsystems:
controlled voltages, "V1" and "V2".   
 
The unit consists of three subsystems
a variable DC voltage source for V1, a variable DC voltage source for V2, and an astable  
a variable DC voltage source for V1, a variable DC voltage source for V2, and an astable  
multivibrator that drives the coil of a relay that switches the output between V1 and V2.
multivibrator that drives the coil of a relay that switches the output between V1 and V2.
Line 11: Line 13:
The 067-0596-00 is specified as part of calibration procedure for the [[141|141A]].
The 067-0596-00 is specified as part of calibration procedure for the [[141|141A]].


==Manuals==
* [http://w140.com/tek_067-0596-00.pdf Tektronix 067-0596-00 Manual (PDF)]
* [http://w140.com/tek_067-0596-00.pdf Tektronix 067-0596-00 Manual (PDF)]


==Pictures==
<gallery>
<gallery>
File:067-0596-00 waveform.jpg
067-0596-00 waveform.jpg
Image:067-0596-00 schem.png
067-0596-00 schem.png
Image:067-0596-00 front.jpg
067-0596-00 front.jpg
Image:067-0596-00 right.jpg
067-0596-00 right.jpg
Image:067-0596-00 top.jpg
067-0596-00 top.jpg
Image:067-0596-00 top2.jpg
067-0596-00 top2.jpg
Image:067-0596-00 bottom.jpg
067-0596-00 bottom.jpg
</gallery>
</gallery>


[[Category:Calibration fixtures]]
[[Category:Calibration fixtures]]
[[Category:Pulse generators]]
[[Category:Pulse generators]]

Revision as of 22:41, 4 July 2016

The Tektronix 067-0596-00 Chopped Voltage Reference Calibration Fixture is a signal generator that produces an approximately square waveform that alternates between two precisely controlled voltages, "V1" and "V2".

The unit consists of three subsystems − a variable DC voltage source for V1, a variable DC voltage source for V2, and an astable multivibrator that drives the coil of a relay that switches the output between V1 and V2. Each of the three subsystems has its own floating power supply (isolated secondary) coming off a power transformer that they share.

The 067-0596-00 uses an Airpax A175 chopper to switch the output between V1 and V2.

The 067-0596-00 is specified as part of calibration procedure for the 141A.