The 560 series scopes which were introduced with the [[560]] and [[561]] in 1961 were tube scopes that began to introduce some solid state circuitry. | The 560 series scopes which were introduced with the [[560]] and [[561]] in 1961 were tube scopes that began to introduce some solid state circuitry. | ||
They | The 560 series includes the [[560]], [[506]], [[561]], [[564]], [[565]], [[567]], and [[568]]. | ||
These seven oscilloscope mainframes have the following in common: | |||
* They accept [[560-series plug-ins]] (the 567 additionally accepts the [[6R1]] or [[6R1A]] plug-ins) | |||
* They have linear power supplies (exception: the 560 power supply is basically a switch-mode power supply) | |||
* They require the plug-ins to drive the CRT vertical and horizontal deflection plates directly (exception: the 565, which includes built-in trigger, timebase, and horizontal amplifier circuitry) | |||
* They don't use post-deflection acceleration of the CRT beam | |||
* They were introduced between 1961 and 1967 | |||
* They don't contain a vertical [[delay line]] (some plug-ins, e.g., the [[3A6]] have built-in delay lines) | |||
560-series | The 560 series of plug-ins comprises the 2-series models (e.g., the [[2A60]] and [[2B67]], | ||
and the 3-series models (e.g., the [[3A1]] and [[3B3]]). | |||
The only | The 3-series models are later and use more power than the 2-series models. | ||
The 3-series plug-ins consume more power than the power supply in the 560 and 561 can deliver. | |||
The [[560]] and [[561]] are only for use with 2-series plug-ins. | |||
When the 561A replaced the original 561, one of the benefits it brought was a power supply capable of meeting the current demands | |||
of 3-series plug-ins. | |||
The | Having the vertical and horizontal deflection amplifiers in the plug-ins rather than in the mainframe has pros and cons. | ||
Pro: | |||
* Lower cost for an entry-level configuration. No need for expensive high-speed amplifiers anywhere in the system. | |||
* Bandwidth can be upgraded later by adding faster plug-ins. | |||
* Replacing plug-ins has a high likelihood of fixing problems, unless there is a problem in the power supply or CRT. | |||
Con: | |||
* The signal path of the plug-in to mainframe interface is not as well standardized as it is on [[500-series scopes]] or [[7000-series scopes]]. This is primarily due to variability in deflection sensitivity of CRTs. Checking calibration after changing plug-ins is a recommended. | |||
* Since each plug-in contains deflection amplifiers, the plug-ins cost more than a plug-in with equivalent functionality for a mainframe that has built-in deflection amplifiers. The cost of the deflection amplifiers adds up if the customer wants several different plug-ins at the high-speed end of the 560-series range. | |||
<gallery widths="150" heights="180"> | <gallery widths="150" heights="180"> | ||
Tek 560 1.jpeg | '''[[560|560 - Basic mainframe]]''' (1961) | Tek 560 1.jpeg | '''[[560|560 - Basic mainframe]]''' (1961) | ||
Tek 506 331023143159.jpg | '''[[506|506 - 20 MHz mainframe]]''' (?) | |||
Tek 561s.jpg | '''[[561]]''' (1961) | Tek 561s.jpg | '''[[561]]''' (1961) | ||
561a-2.jpg | '''[[561A]]''' (1962) | 561a-2.jpg | '''[[561A]]''' (1962) |
Revision as of 04:31, 13 December 2017
The 560 series scopes which were introduced with the 560 and 561 in 1961 were tube scopes that began to introduce some solid state circuitry. The 560 series includes the 560, 506, 561, 564, 565, 567, and 568. These seven oscilloscope mainframes have the following in common:
- They accept 560-series plug-ins (the 567 additionally accepts the 6R1 or 6R1A plug-ins)
- They have linear power supplies (exception: the 560 power supply is basically a switch-mode power supply)
- They require the plug-ins to drive the CRT vertical and horizontal deflection plates directly (exception: the 565, which includes built-in trigger, timebase, and horizontal amplifier circuitry)
- They don't use post-deflection acceleration of the CRT beam
- They were introduced between 1961 and 1967
- They don't contain a vertical delay line (some plug-ins, e.g., the 3A6 have built-in delay lines)
The 560 series of plug-ins comprises the 2-series models (e.g., the 2A60 and 2B67, and the 3-series models (e.g., the 3A1 and 3B3). The 3-series models are later and use more power than the 2-series models. The 3-series plug-ins consume more power than the power supply in the 560 and 561 can deliver. The 560 and 561 are only for use with 2-series plug-ins. When the 561A replaced the original 561, one of the benefits it brought was a power supply capable of meeting the current demands of 3-series plug-ins.
Having the vertical and horizontal deflection amplifiers in the plug-ins rather than in the mainframe has pros and cons.
Pro:
- Lower cost for an entry-level configuration. No need for expensive high-speed amplifiers anywhere in the system.
- Bandwidth can be upgraded later by adding faster plug-ins.
- Replacing plug-ins has a high likelihood of fixing problems, unless there is a problem in the power supply or CRT.
Con:
- The signal path of the plug-in to mainframe interface is not as well standardized as it is on 500-series scopes or 7000-series scopes. This is primarily due to variability in deflection sensitivity of CRTs. Checking calibration after changing plug-ins is a recommended.
- Since each plug-in contains deflection amplifiers, the plug-ins cost more than a plug-in with equivalent functionality for a mainframe that has built-in deflection amplifiers. The cost of the deflection amplifiers adds up if the customer wants several different plug-ins at the high-speed end of the 560-series range.
-
560 - Basic mainframe (1961)
-
561 (1961)
-
561A (1962)
-
561B - Solid state scope (1969)
-
564 - Storage scope (1962-1968?)
-
RM564 - Storage scope (1962-1968?)
-
565 - Dual-beam scope, two plug-ins; built-in trigger, sweep, and horizontal amplifier (1963)
-
568 - Sampling scope (1967)