PS503: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
mNo edit summary |
||
Line 10: | Line 10: | ||
{{BeginSpecs}} | {{BeginSpecs}} | ||
{{SpecGroup | Variable outputs }} | {{SpecGroup | Variable outputs }} | ||
{{Spec | Output voltage | 0 to +20 V and 0 to | {{Spec | Output voltage | 0 to +20 V and 0 to −20 V }} | ||
{{Spec | Current limit | <100 mA to >1 A (0.4 A if used in low power compartment) }} | {{Spec | Current limit | <100 mA to >1 A (0.4 A if used in low power compartment) }} | ||
{{Spec | Ripple and noise | <3 mV<sub>p-p</sub> @ 1 A }} | {{Spec | Ripple and noise | <3 mV<sub>p-p</sub> @ 1 A }} |
Revision as of 13:07, 10 August 2018
The Tektronix PS503 is a triple power supply plug-in for the TM500 system.
It supplies 0 to −20 V and 0 to +20 V at 1 A (0.4 A in low power compartments) as well as +5 V at 1 A.
The variable supplies can be adjusted independently or can track one another, and are floating; the 5 V output is ground referenced.
Key Specifications
— Variable outputs — | |
Output voltage | 0 to +20 V and 0 to −20 V |
Current limit | <100 mA to >1 A (0.4 A if used in low power compartment) |
Ripple and noise | <3 mVp-p @ 1 A |
— Fixed output — | |
Output voltage3 | 5 V ±5%, 1 A (ground referenced) |
Current limit | fixed 1 A |
Ripple and noise | <3 mVp-p @ 1 A |
Rear interface signals
- +20 V output (22A)
- −20 V output (22B)
- ±20 V common (24A, 24B)
(the connections below require various jumper changes in the PS503 as described in the manual)
- Remote resistor programming (via 25A, 25B)
- Remote voltage programming (via 25A, 25B)
- Remote sensing (+Sense 23A, −Sense 23B)
Pictures
-
PS503A
-
PS503A
-
PS503A
-
Switch S95 in rear of PS503 (detects high power compartment)