{{{manufacturer}}} 
Spectrum Analyzer 9 kHz to 18.0 GHz
Tektronix RSA518A

Produced from (?) to (?)

Manuals
Manuals – Specifications – Links – Pictures


The RSA518A is a ruggedized portable spectrum analyzer meant for field or lab use with a frequency range of 9 kHz to 18.0 GHz. The user interface and display resides on a user-provided PC running SignalVu-PC software or a user-developed application. The host PC provides all power, control, and data signals over the USB 3.0 cable included with the instrument. An available SW API is provided to allow you to create your own custom signal processing application. A self guided demo board and guide can be found here RSA-DKIT.

Signal processing while running SignalVu-PC software provides real-time processing of for general signal analysis, analog modulation analysis, and RF measurements. This software can be programmed through the program’s interface or through the use of the included application programming interface (API). Post processing analysis of large sets of recorded data can be performed across multiple sets using DataVu-PC software.

The optional tracking generator enables gain/loss measurements for quick tests of filters, duplexers and other network elements, and the user can add cable and antenna measurements of VSWR, return loss, distance to fault and cable loss as needed.

Front panel inputs/outputs are: RF IN N connector or optionally user could select a Planar Crown connector (50Ω; ± 40V DC, +33 dBm max); RF Out/REFL In N connector (Tracking generator source connector); Ref In BNC connector (External frequency reference) ; Trig In BNC connector (10k Ω input; 5V TTL 10); ANT In SMA connector (To connect optional GPS/GNSS antenna); and USB 3.0 USB connector (USB 3.0 Type A connector) .

Rear panel input: External DC Power (For charging the battery pack or providing DC supply to instrument without battery)

Key Specifications

{{Spec | Ext DC Input | 18 V (+12 V to +19.95 V limits)
Frequency Range 9 kHz to 18.0 GHz
RF Input impedance 50 Ω
Maximum Safe Input Power +33 dBm ± 40V DC Max, RF Attn ≥20 dB
Input RF Attenuator 0 dB to 51 dB (1 dB step)
Dynamic Range (Spurious Free) 70 dB
Reference Level Range -170 dBm to +40 dBm (0.1 dB step)
Sweep Speed (Full speed) 70 GHz/sec (RBW: 1 MHz); 60 GHz/sec (RBW: 100 kHz); 15.7 GHz/sec (RBW: 10 kHz); 1.7 GHz/sec (RBW: 1 kHz)
Acquisition (IF) Bandwidth 40 MHz
Real-Time IF Acq Data and Bit Width 112 Ms/s, 16 bits
Minimum Signal Duration for 100% POI 15 µsec to 40 MHz
Trigger Threshold Range 0 dB to -50 dB from reference level, for trigger levels > 30 dB above noise floor
Trigger Types Rising edge, falling edge, schmitt
Trigger Levels Positive-going: 1.6 V min, 2.1 V max; Negative-going: 1.0 V min, 1.35 V max
Displayed Average Noise (Preamp off) −130 dBm/Hz to −145 dBm/Hz
Phase Noise (1 GHz CF) ≤-94 dBc/Hz to ≤-116 dBc/Hz
Included Accessories Quick-Start manual; USB 3.0 cable (2 M); Screw lock; Shoulder strap; Carrying case (with room for unit, tablet, accessories); WFM200BA Li-Ion rechargeable battery pack; Battery pack instructions; AC power adapter; Power core; SignalVu-PC software, API and documentation file, and USB memory
Weight 3.4 kg (7.5 lbs) w/o battery, 3.85 kg (8.5 lbs) w/battery
Power Dissipation (fully loaded) 15 W max
Battery Voltage and Capacity (nominal) 14.4 V, 6140 mAh
Battery Tech and Life Li-Ion Smart Battery; 4 hours continuous operation; 2 years storage
Operating Atmospherics Temperatures: -10 °C to +55 °C; Humidity: 5% to 95% from +10 °C to +30 °C; Altitude: Up to 5000 m (16,404 ft)

Instrument Options

  • Opt. 04: Tracking generator (10 Mhz to 7.5 GHz)

Service Options

  • Opt. C3: Calibration Service 3 Years
  • Opt. C5: Calibration Service 5 Years
  • Opt. D1: Calibration Data Report
  • Opt. D3: Calibration Data Report 3 Years (with Opt. C3)
  • Opt. D5: Calibration Data Report 5 Years (with Opt. C5)
  • Opt. R5: Repair Service 5 Years (including warranty)

Recommended Accessories

Pictures