Used with a [[3S7]], a TDR system is formed. | Used with a [[3S7]], a TDR system is formed. | ||
The pulse is produced by a 21mA, 1.5pF [[tunnel diodes|tunnel diode]], | The pulse is produced by a 21mA, 1.5pF [[tunnel diodes|tunnel diode]], | ||
CR587, made by GE with Tektronix part number 152-0489-00. | CR587, made by GE with Tektronix part number [[152-0489-00]]. | ||
* [http://w140.com/tek_3s7_3t7.pdf Tektronix 3S7/3T7 Manual (PDF)] | * [http://w140.com/tek_3s7_3t7.pdf Tektronix 3S7/3T7 Manual (PDF)] |
Revision as of 21:38, 19 February 2012
The Tektronix Type 3T7 is a sampling timebase and pulser plug-in for 560-series scopes. Used with a 3S7, a TDR system is formed. The pulse is produced by a 21mA, 1.5pF tunnel diode, CR587, made by GE with Tektronix part number 152-0489-00.
-
Front
-
Left
-
Right
-
Top
-
Bottom