The '''Tektronix CSA803''' is a digital sampling oscilloscope that takes two [[:Category:11800 series sampling plugins|11800 series plug-in sampling modules]]. The two left plug-in slots are supplying DC only and are supposed to be used for optical to electrical converters like the [[SD-48]]. From the specifications of the CSA803C and the [[11801C]] it seems that they are identical, except for omitting the two left plug-ins and the trigger ×10 function in the CSA803. | The '''Tektronix CSA803''' is a digital sampling oscilloscope that takes two [[:Category:11800 series sampling plugins|11800 series plug-in sampling modules]]. The two left plug-in slots are supplying DC only and are supposed to be used for optical to electrical converters like the [[SD-48]]. From the specifications of the CSA803C and the [[11801C]] it seems that they are identical, except for omitting the two left plug-ins and adding the trigger ×10 prescaler function in the CSA803. | ||
{{BeginSpecs}} | {{BeginSpecs}} |
Revision as of 19:15, 16 November 2020
The Tektronix CSA803 is a digital sampling oscilloscope that takes two 11800 series plug-in sampling modules. The two left plug-in slots are supplying DC only and are supposed to be used for optical to electrical converters like the SD-48. From the specifications of the CSA803C and the 11801C it seems that they are identical, except for omitting the two left plug-ins and adding the trigger ×10 prescaler function in the CSA803.
Key Specifications
Vertical Resolution | 8 bits - 25 points/div |
---|---|
Input Sensitivity | 2 to 255 mV/div in 1 mV/div steps |
Record Duration | 10 ps to 50 ms |
Record Length | 512, 1024, 2048, 4096, 5120 samples |
Sample Rate | up to 200 kHz |
Jitter | 1.1 ps RMS + 4 ppm of position (typical) |
Maximum Trigger Input | 1 Vp-p direct, 2.5 Vp-p prescaler |
Trigger Sensitivity | 50 mV, DC - 4 GHz, AC coupled trigger prescaler to 10 GHz |
Prices
1990: $23,950 (2018 value: $45,730)