Revision as of 07:12, 2 April 2021
The Tektronix A6302 aka P6302 is a 50 MHz, 20 A current probe. It requires an AM503, AM5030 or 11A16 amplifier for operation.
There is also an A6302XL version with 8 m instead of 2 m cable, and 17 MHz bandwidth.
Key Specifications
Bandwidth | DC-50 MHz (6302XL: 17 MHz) |
---|---|
Input range | 20 A continuous, 50 A peak, ≤100 A · μs (with 11A16: 10.5 A continuous), derate to 2.5 A @ 10 MHz |
Sensitivity | 1 mA/Div to 5 A/Div, 1−2−5 (with AM503) |
Noise | ≤250 μA (@ ≤200 MHz amplifier BW) |
Insertion impedance | 0.1 Ω @ 1 MHz, 0.5 Ω @ 50 MHz |
Manuals
- Tektronix A6302/6302XL Manual 070-3905-04 (PDF)
- Tektronix A6302/6302XL Manual 070-3905-05 (PDF)
- A6302 @ Fred PA4TIM's pages
Links
Pictures
-
A6302 probe
-
-
-
circuit diagram
-
-
-
-
-
-
-
component view
-
Sleeve pulled out few mm
-
Amphenol Connector Disassembled