It is used for measuring the distortion (spectral impurity) of an oscillator by eliminating the fundamental frequency of the oscillator (primarily the [[SG505]]), so the residual harmonics can be measured.
It is used for measuring the distortion (spectral impurity) of an oscillator by eliminating the fundamental frequency of the oscillator (primarily the [[SG505]]), so the residual harmonics can be measured.
The circuit topology is a passive double-T RC notch filter with a precision 600 Ω load and a 60 dB attenuator.  The module has no connections to the TM500 mainframe, requiring no power supply.
{{BeginSpecs}}
{{Spec|Notch frequency | 10 Hz, 20 Hz, 100 Hz, 1 kHz, 10 kHz, 20 kHz, 50 kHz, 100 kHz; ±2% }}
{{Spec|Notch depth| ≥100 dB at 10 Hz and 20 Hz, ≥60 dB otherwise }}
{{EndSpecs}}
Load impedance must be ≥1 MΩ ±5% // ≤75 pF including cabling and spectrum analyzer input capacitance.  Input source impedance must be 600 Ω ±5%.