TDS2024: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
m (→‎top: clean up, replaced: |manufacturer=Tektronix → |manufacturer=Tektronix |series=TDS series scopes)
 
(5 intermediate revisions by 2 users not shown)
Line 1: Line 1:
{{Oscilloscope Sidebar |
{{Oscilloscope Sidebar |manufacturer=Tektronix |series=TDS series scopes|designers= |
title=Tektronix TDS2024 |
model= TDS2024 |
summary=Digital Storage 200 MHz 4-channel scope |
summary=Digital Storage 200 MHz 4-channel scope |
image=TDS2024_Waveform_image.jpg |
image=TDS2024_Waveform_image.jpg |
Line 14: Line 14:
* [[Media:TDS1000 AND TDS2000 SERIES FIRMWARE UPDATE.txt| TDS1000 AND TDS2000 Series Firmware Update Notice]] (786 B TXT)
* [[Media:TDS1000 AND TDS2000 SERIES FIRMWARE UPDATE.txt| TDS1000 AND TDS2000 Series Firmware Update Notice]] (786 B TXT)
}}
}}
The '''Tektronix TDS2024''' is a four-channel, 200 MHz, 1 GS/s digital scope with a color LCD screen.  An External trigger input on front, and the rear mounted optional TDS2MEM Communication Module provides a CompactFlash card slot, Centronics-type printer port, RS-232, and GPIB rear ports for convenient inter-connectivity.
The '''Tektronix TDS2024''' is a four-channel, 200 MHz, 1 GS/s digital scope with a color LCD screen.


Easy access to the MATH MENU button provides waveform adjustments (CH1-CH2, CH2-CH1, CH3-CH4, CH4-CH3, CH1+CH2, CH3+CH4) along with FFT (spectrum, harmonics, distortion, noise, impulse, vibration) measurements.  Measurements can also be performed for time (frequency) and voltage (amplitude).  Repetitive signals can be captured and averaged to remove noise, or captured as a single-shot signal.
An optional rear-mounted [[TDS2MEM]] Communication Module provides a CompactFlash card slot, [[GPIB]], [[RS-232]], and Centronics-type [[parallel printer interface]]s.
 
The MATH MENU button provides waveform adjustments (CH1-CH2, CH2-CH1, CH3-CH4, CH4-CH3, CH1+CH2, CH3+CH4) along with FFT (spectrum, harmonics, distortion, noise, impulse, vibration) measurements.  Measurements can also be performed for time (frequency) and voltage (amplitude).  Repetitive signals can be captured and averaged to remove noise, or captured as a single-shot signal.


Triggering of signal capturing is available through a comprehensive TRIG MENU providing Edge (rising or falling), Video (NTSC, PAL, SECAM), and Pulse Width (or Glitch) triggering on CH1, CH2, CH3, CH4, Ext and AC Line sources.
Triggering of signal capturing is available through a comprehensive TRIG MENU providing Edge (rising or falling), Video (NTSC, PAL, SECAM), and Pulse Width (or Glitch) triggering on CH1, CH2, CH3, CH4, Ext and AC Line sources.


{{BeginSpecs}}
{{BeginSpecs}}
Line 35: Line 35:
==Pictures==
==Pictures==
<gallery>
<gallery>
TDS2024-Front-panel-board-and-lcd.jpg | Front Panel Board and LCD
Tek-TDS2024_inside_top.jpg| TDS2024 inside top view
Tek-TDS2024-inside-back.jpg| Inside TDS2024 back side
Tek-2024-PSU.jpg| TDS2024 Power Supply Unit
Tek-TDS2024 main board top side.jpg| TDS2024 Main Board Top Side
TEK-TDS2024-mainbaoard-bottom.jpg| TDS2024 Main Board Bottom Side
Tek-TDS2024-front panel board back side broken rotary switch.jpg| TDS2024 front panel board back side with a broken rotary switch
</gallery>
</gallery>




[[Category:TDS1000 series scopes]]
[[Category:TDS2000 series scopes]]

Latest revision as of 07:45, 11 August 2021

Tektronix TDS2024
Digital Storage 200 MHz 4-channel scope
Tektronix TDS2024

Produced from 2005 to (?)

Manuals
Manuals – Specifications – Links – Pictures

The Tektronix TDS2024 is a four-channel, 200 MHz, 1 GS/s digital scope with a color LCD screen.

An optional rear-mounted TDS2MEM Communication Module provides a CompactFlash card slot, GPIB, RS-232, and Centronics-type parallel printer interfaces.

The MATH MENU button provides waveform adjustments (CH1-CH2, CH2-CH1, CH3-CH4, CH4-CH3, CH1+CH2, CH3+CH4) along with FFT (spectrum, harmonics, distortion, noise, impulse, vibration) measurements. Measurements can also be performed for time (frequency) and voltage (amplitude). Repetitive signals can be captured and averaged to remove noise, or captured as a single-shot signal.

Triggering of signal capturing is available through a comprehensive TRIG MENU providing Edge (rising or falling), Video (NTSC, PAL, SECAM), and Pulse Width (or Glitch) triggering on CH1, CH2, CH3, CH4, Ext and AC Line sources.

Key Specifications

Bandwidth and Channels 200 MHz; Bandwidth is 20 MHz at 2 mV/div; 4 Channels
Vertical Sensitivity 2 mV to 5 V/div with calibrated fine adjustment
Time Base Range 2.5 ns to 50 s/div
Sample Rate 1.0 GS/s on each channel
Record Length 2.5 K points
Automatic Waveform Measurements Period, Frequency, +Width, -Width, Rise Time, Fall Time, Max, Min, Peak-to-Peak, Mean, Cycle RMS
Waveform Processing Operators (Add, Subtract, FFT); FFT (Windows: Hanning, Flat Top, Rectangular; 2048 sample points; Autoset Menu (Single-button, automatic setup of all channels for vertical, horizontal, and trigger systems with undo autoset)
Autoset Menu Square Wave (Single-cycle, Multi-cycle, Rising or Falling Edge); Sine Wave (Single-cycle, Multi-cycle, FFT Spectrum); Video (NTSC, PAL, SECAM) Field: All, Odd or Even Line:All or Selective Line Number

Pictures