The Tektronix P6054 is a 500 MHz, x10, passive, miniature modular probe. It is the same as the P6053 but without a readout pin.
Key Specifications
Bandwidth | 500 MHz (9' model: 175 MHz) |
---|---|
Rise time | ≤0.7 ns (9' model: ≤2 ns) |
Cable length | 3.5 ft, 6 ft or 9 ft |
Input impedance | 10 MΩ // 9.5 pF (3.5'), 12 pF (6'), 13.5 pF (9') |
Maximum input | 500 V DC + peak AC to 3.5 MHz |
Compensation range | 1 MΩ // 15-24 pF |
Accessories
- hook tip (206-0114-00)
- retractable-hook tip (013-0107-00)
- bayonet-ground adapter (013-0085-00)
- minigator clip (344-0046-00)
- probe holder (352-0234-00)
- 3-inch ground lead (175-0848-00)
- 5-inch ground lead (175-0848-01)
- insulating tube (166-0404-01)
- (opt) 017-0076-00 probe tip to GR adapter
- (opt) 013-0084-01 probe tip to BNC adapter