|manufacturer=Tektronix | |manufacturer=Tektronix | ||
|model=P6007 | |model=P6007 | ||
|summary=25 MHz, | |summary=25 MHz, 100×, HV, Passive Probe | ||
|image=Tek p6007 1.jpg | |image=Tek p6007 1.jpg | ||
|caption=P6007 | |caption=P6007 | ||
Line 10: | Line 10: | ||
|designers= | |designers= | ||
|manuals= | |manuals= | ||
* [[Media:070-0388-01.pdf|Tektronix P6007 Manual | * [[Media:070-0388-01.pdf|Tektronix P6007 Manual]] | ||
* [http://w140.com/tek_p6007_p6009_p6015_cat.pdf Tektronix P6007 P6009 P6015 Catalog Description | * [http://w140.com/tek_p6007_p6009_p6015_cat.pdf Tektronix P6007 P6009 P6015 Catalog Description] | ||
}} | }} | ||
The '''Tektronix P6007''' is a medium voltage, 100×, passive probe for use with 1 MΩ input scopes. | |||
The '''Tektronix P6007''' is a medium voltage, | |||
It has a BNC connector with no [[readout encoding pin]]. | It has a BNC connector with no [[readout encoding pin]]. | ||
{{BeginSpecs}} | {{BeginSpecs}} | ||
{{Spec | Bandwidth | 25 MHz }} | {{Spec | Bandwidth | 25 MHz }} | ||
{{Spec | Attenuation | | {{Spec | Attenuation | 100× ±3% }} | ||
{{Spec | Maximum Voltage | 1.5 kV DC or 4.2 kV AC p-p, must be derated at higher frequencies }} | {{Spec | Maximum Voltage | 1.5 kV DC or 4.2 kV AC p-p, must be derated at higher frequencies }} | ||
{{Spec | Input Impedance | 10 MΩ plus 2.0 to 2.8 pF, depending on cable length and scope input capacitance }} | {{Spec | Input Impedance | 10 MΩ plus 2.0 to 2.8 pF, depending on cable length and scope input capacitance }} |