TDS544A: Difference between revisions
Jump to navigation
Jump to search
Jaredcabot (talk | contribs) (Added software) |
Jaredcabot (talk | contribs) (Added manuals) |
||
(3 intermediate revisions by the same user not shown) | |||
Line 10: | Line 10: | ||
* [[Media:061-4094-02.pdf|TDS, TLS & CTS FDD Replacement Instructions 061-4094-02]] | * [[Media:061-4094-02.pdf|TDS, TLS & CTS FDD Replacement Instructions 061-4094-02]] | ||
* [[Media:070-8432-04.pdf|TLS Logic Scope and TDS Series Oscilloscopes Rackmount Installation 070-8432-04]] | * [[Media:070-8432-04.pdf|TLS Logic Scope and TDS Series Oscilloscopes Rackmount Installation 070-8432-04]] | ||
* [[Media:070-8567-01.pdf|Option 13 RS-232/Centronics Hardcopy Interface Instruction Manual 070-8567-01]] | |||
* [[Media:070-8582-01.pdf|Option 2F Advanced DSP Math Instruction Manual 070-8582-01]] | |||
* [[Media:070-8748-02.pdf|TDS Family Opt 05 Video Trigger Interface Instruction Manual 070-8709-02]] | * [[Media:070-8748-02.pdf|TDS Family Opt 05 Video Trigger Interface Instruction Manual 070-8709-02]] | ||
* [[Media:070-8919-00.pdf|TTiP TDS Telecommunication Templates & i-Pattern Software 070-8919-00]] | * [[Media:070-8919-00.pdf|TTiP TDS Telecommunication Templates & i-Pattern Software 070-8919-00]] | ||
Line 53: | Line 55: | ||
* [[Media:Tek_TDS500_Field_Adjustment_Software.zip|TDS500 Field Adjustment Software]] (ZIP) | * [[Media:Tek_TDS500_Field_Adjustment_Software.zip|TDS500 Field Adjustment Software]] (ZIP) | ||
* [[Media:TDS500-500A_V1.4_Field_Adjustment_Software.zip|TDS544A V1.4 Field Adjustment Software]] (ZIP) | * [[Media:TDS500-500A_V1.4_Field_Adjustment_Software.zip|TDS544A V1.4 Field Adjustment Software]] (ZIP) | ||
* [[Media:TDS500-500A_V1.6_Field_Adjustment_Software.zip|TDS544A V1.6 Field Adjustment Software]] (ZIP) | * [[Media:TDS500-500A_V1.6_Field_Adjustment_Software.zip|TDS544A V1.6 Field Adjustment Software 063-1642-00]] (ZIP) | ||
* [[Media:TDS500-500A_V1.11_Field_Adjustment_Software.zip|TDS544A V1.11 Field Adjustment Software]] (ZIP) | * [[Media:TDS500-500A_V1.11_Field_Adjustment_Software.zip|TDS544A V1.11 Field Adjustment Software]] (ZIP) | ||
<br> | <br> | ||
* [[Media:063-1134-00 V1.2.zip|TDS Family Programming Examples Software 063-1134-00 V1.2]] (ZIP) | |||
* [[Media:066-0002-00.zip|Waveform Converter For Oscilloscopes 066-0002-00]] (ZIP) | * [[Media:066-0002-00.zip|Waveform Converter For Oscilloscopes 066-0002-00]] (ZIP) | ||
* [[Media:066-0087-00.zip|AWE Drivers For Tektronix Oscilloscopes 066-0087-00]] (ZIP) | * [[Media:066-0087-00.zip|AWE Drivers For Tektronix Oscilloscopes 066-0087-00]] (ZIP) | ||
Line 65: | Line 68: | ||
* [[Media:066-0178-00.zip|Example Program To Get Crossing Levels 066-0178-00]] (ZIP) | * [[Media:066-0178-00.zip|Example Program To Get Crossing Levels 066-0178-00]] (ZIP) | ||
* [[Media:066-0179-00.zip|TDS ISF File To CSV File Conversion Utility 066-0179-00]] (ZIP) | * [[Media:066-0179-00.zip|TDS ISF File To CSV File Conversion Utility 066-0179-00]] (ZIP) | ||
* [[Media:066-0183-00.zip|TDS Sandisk Hard Disk Patch Utility 066-0183-00]] (ZIP) | * [[Media:066-0183-00.zip|TDS Sandisk Hard Disk Patch Utility 066-0183-00]] (ZIP) | ||
* [[Media:066-0188-00.zip|Transfer 2 Byte Data From TDS Oscilloscopes QuickBasic 066-0188-00]] (ZIP) | * [[Media:066-0188-00.zip|Transfer 2 Byte Data From TDS Oscilloscopes QuickBasic 066-0188-00]] (ZIP) | ||
* [[Media:066-0194-00.zip|TDS Waveform Logging Sample Program 066-0194-00]] (ZIP) | * [[Media:066-0194-00.zip|TDS Waveform Logging Sample Program 066-0194-00]] (ZIP) | ||
Line 73: | Line 76: | ||
* [[Media:066-0200-00.zip|VB Program To Capture TDS Extended Waveforms 066-0200-00]] (ZIP) | * [[Media:066-0200-00.zip|VB Program To Capture TDS Extended Waveforms 066-0200-00]] (ZIP) | ||
* [[Media:066-0489-00.zip|TDS Series WFM File Formatter 066-0489-00]] (ZIP) | * [[Media:066-0489-00.zip|TDS Series WFM File Formatter 066-0489-00]] (ZIP) | ||
* [[Media: | * [[Media:Wavestar_2012.05.09.11.07.29_16456_EN.zip|Tektronix Wavestar 2012.05.09.11.07.29 16456 EN 066-0934-03]] (ZIP, 102MB) ''Product Key: WSTRO618650124'' | ||
==Firmware== | ==Firmware== |
Latest revision as of 22:13, 1 March 2023
The Tektronix TDS544A is a 500 MHz, 1 GS/s quad-channel digital scope with a color screen.
Specifications
- 500 MHz bandwidth
- color CRT
- sample rates to 1 GSa/s
- 25 automatic measurements
- 4 input channels
- 3.5" floppy drive
- sensitivity of 1 mV to 10 V per division
- time base range of 500 ps to 10 s/div
- waveform Pass/Fail testing
- record lengths of up to 50,000 points
Software
- TDS500 Field Adjustment Software (ZIP)
- TDS544A V1.4 Field Adjustment Software (ZIP)
- TDS544A V1.6 Field Adjustment Software 063-1642-00 (ZIP)
- TDS544A V1.11 Field Adjustment Software (ZIP)
- TDS Family Programming Examples Software 063-1134-00 V1.2 (ZIP)
- Waveform Converter For Oscilloscopes 066-0002-00 (ZIP)
- AWE Drivers For Tektronix Oscilloscopes 066-0087-00 (ZIP)
- File Transfer Utility From TDS Scope To PC 066-0104-00 (ZIP)
- Enhanced Printing Utility for TDS Family (ZIP)
- Tektronix TDS500C/700C Custom Masks 066-0165-00 (ZIP)
- WFM to ASCII Waveform Converter - UNIX Version For Sun Spark Stations 066-0176-00 (ZIP)
- Hardcopy from TDS to PC Using HPIP 82335B Interface Card 066-0177-00 (ZIP)
- Example Program To Get Crossing Levels 066-0178-00 (ZIP)
- TDS ISF File To CSV File Conversion Utility 066-0179-00 (ZIP)
- TDS Sandisk Hard Disk Patch Utility 066-0183-00 (ZIP)
- Transfer 2 Byte Data From TDS Oscilloscopes QuickBasic 066-0188-00 (ZIP)
- TDS Waveform Logging Sample Program 066-0194-00 (ZIP)
- Load TDS Floppy MathCAD Files Into MathCAD 066-0196-00 (ZIP)
- Transfer TDS Hardcopy Screens To PC Via GPIB 066-0197-00 (ZIP)
- Transfer Setups Between TDS Oscilloscopes 066-0198-00 (ZIP)
- VB Program To Capture TDS Extended Waveforms 066-0200-00 (ZIP)
- TDS Series WFM File Formatter 066-0489-00 (ZIP)
- Tektronix Wavestar 2012.05.09.11.07.29 16456 EN 066-0934-03 (ZIP, 102MB) Product Key: WSTRO618650124
Firmware
- TDS544A v3.8.4e Firmware (ZIP)
Options
- 05 - Video Trigger
- 13 - RS-232/Centronics Hardcopy Interface. Standard on TDS524A-TDS544A.
- 1F - FILE SYSTEM, standard on TDS524A-TDS544A.
- 1K - K420 Oscilloscope Cart without power strip
- 1M - 50k Memory Length
- 1R - Rackmount
- 23 - Add two each P6205 Active Probes
- 25 - Add P6563A, four SMD probes
- 2F - Advanced DSP Math
Links
- TDS544A CRT to LCD conversion (YouTube)