The P6019 and [[P6020]] split-core AC current probes were introduced in  
{{Probe Sidebar
1966 together with passive terminations and an active amplifier Type  
|manufacturer=Tektronix
134.  
|model=P6019
|summary=Oscilloscope current probe
|image=Image needed.jpg
|caption=Tektronix P6019
|for=134
|introduced=1966
|discontinued=(?)
|manuals=
* [https://w140.com/P6019-P6020.djvu Tektronix P6019 / P6020 Manual (DjVu)] (contains a compilation of scans from two editions of the P6019/P6020 manual)
* [[Media:Tek p6020 fcp july 1967.pdf]]
}}
The '''Tektronix P6019''' is a 125 turn split-core AC current probe introduced in 1966 together with its 011-0078-00 passive termination and the [[134|Type 134]] amplifier.


The probes had no internal frequency compensation components,
The '''Tektronix P6020''', introduced at the same time, is a 50 turn, higher frequency companion introduced at the same time.
contrary to their 1969 successor types P6021 and P6022.


The djvu-file contains a compilation of scans from two editions of the
The P6019 and P6020 have no internal frequency compensation components, contrary to their 1969 successors, [[P6021]] and [[P6022]].
134--P6019/P6020 manual.


* [http://w140.com/P6019-P6020.djvu Tektronix P6019 / P6020 Manual (DjVu)]
==Specifications==
{| class="wikitable"
!
! P6019 + 011-0078-00 passive termination
! P6019 + [[134]]
! P6020 + 011-0079-00 passive termination
! P6020 + [[134]]
|-
! Sensitivity
| 2 mA/mV or 10 mA/mV  || 1 mA/Div to 1 A/Div (scope @ 50 mV/Div)
| 1 mA/mV or 10 mA/mV  || 1 mA/Div to 1 A/Div (scope @ 50 mV/Div)
|-
! Bandwidth (-3 dB)
| 60 MHz @ 10 mA/mV    ||  > 40 MHz
| 200 MHz @ 10 mA/mV  ||  > 70 MHz
|-
! LF limit (-3 dB)
| 450 Hz @ 2 mA/mV, 120 Hz @ 10 mA/mV  ||  < 12 Hz   
| 6500 Hz @ 1 mA/mV, 775 Hz @ 10 mA/mV  ||  < 50 Hz   
|-
! Maximum current
| colspan="2" align="center" | 15 A<sub>p-p</sub>
| colspan="2" align="center" | 6 A<sub>p-p</sub>
|}
 
==Links==
* [http://www.analogdesign.be/vintage-gear/tektronix-p6019-ac-current-probe P6019 @ analogdesign.be]
 
==Pictures==
 
<gallery>
011-0079-00 1.jpg | [[011-0079-00]] passive termination for P6020
011-0079-00 2.png | [[011-0079-00]] passive termination for P6020
</gallery>


[[Category:Oscilloscope current probes]]
[[Category:Oscilloscope current probes]]

Latest revision as of 22:46, 30 March 2023

Tektronix P6019
Oscilloscope current probe
Tektronix P6019

Compatible with 134

Produced from 1966 to (?)

Manuals


Manuals – Specifications – Links – Pictures

The Tektronix P6019 is a 125 turn split-core AC current probe introduced in 1966 together with its 011-0078-00 passive termination and the Type 134 amplifier.

The Tektronix P6020, introduced at the same time, is a 50 turn, higher frequency companion introduced at the same time.

The P6019 and P6020 have no internal frequency compensation components, contrary to their 1969 successors, P6021 and P6022.

Specifications

P6019 + 011-0078-00 passive termination P6019 + 134 P6020 + 011-0079-00 passive termination P6020 + 134
Sensitivity 2 mA/mV or 10 mA/mV 1 mA/Div to 1 A/Div (scope @ 50 mV/Div) 1 mA/mV or 10 mA/mV 1 mA/Div to 1 A/Div (scope @ 50 mV/Div)
Bandwidth (-3 dB) 60 MHz @ 10 mA/mV > 40 MHz 200 MHz @ 10 mA/mV > 70 MHz
LF limit (-3 dB) 450 Hz @ 2 mA/mV, 120 Hz @ 10 mA/mV < 12 Hz 6500 Hz @ 1 mA/mV, 775 Hz @ 10 mA/mV < 50 Hz
Maximum current 15 Ap-p 6 Ap-p

Links