{{Spec | Attenuation | Adjustable to ×10 }} | {{Spec | Attenuation | Adjustable to ×10 }} | ||
{{Spec | CMRR | 10,000:1 on [[11A33]], 20,000:1 on [[7A13]] }} | {{Spec | CMRR | 10,000:1 on [[11A33]], 20,000:1 on [[7A13]] }} | ||
{{Spec | Bandwidth | 150 MHz}} | |||
{{Spec | Max. input | ±500 V Maximum Common Mode Voltage }} | {{Spec | Max. input | ±500 V Maximum Common Mode Voltage }} | ||
{{EndSpecs}} | {{EndSpecs}} |
Revision as of 05:47, 18 April 2023
The Tektronix P6135(A) is a differential probe pair matched to minimize differences in impedance and signal delay, to maintain CMRR up to 20,000:1 when used with differential amplifiers such as the 7A13, 7A22 or 11A33.
The P6135 is a subminiature modular probe with a limited compensation range around 15 pF. The P6135A is a larger compact modular probe and comes with three different tips for increased compensation range.
Key Specifications
Scope Impedance Compensation Range | P6135: 1 MΩ // 13-17 pF; P6135A: 1 MΩ // 13-17 pF (red tip), 1 MΩ // 18-22 pF (black tip) and 1 MΩ // 45-49 pF (blue tip) |
---|---|
Attenuation | Adjustable to ×10 |
CMRR | 10,000:1 on 11A33, 20,000:1 on 7A13 |
Bandwidth | 150 MHz |
Max. input | ±500 V Maximum Common Mode Voltage |