P6012: Difference between revisions
Jump to navigation
Jump to search
m (Text replacement - "Category:1 MOhm Oscilloscope Probes" to "Category:1 MΩ Oscilloscope probes") |
No edit summary |
||
(7 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
The '''Tektronix P6012''' is a passive 10× probe with 33 MHz bandwidth | {{Probe Sidebar | ||
|manufacturer=Tektronix | |||
|model=P6012 | |||
|summary=33 MHz passive 10× probe | |||
|image=Tek-p6012.png | |||
|caption=Tektronix P6012 | |||
|for=1 MΩ scope inputs | |||
|introduced=1966 | |||
|discontinued=(?) | |||
|manuals= | |||
* [[Media:070-0601-02.pdf|Tektronix P6012 Manual]] | |||
}} | |||
The '''Tektronix P6012''' is a passive 10× probe with 33 MHz bandwidth. | |||
It comes with 3.5', 6', or 9' cable and a [[BNC connector]]. | |||
[[ | It has a small diameter probe body, making it more useful in crowded circuitry. | ||
{{BeginSpecs}} | |||
{{Spec | Bandwidth | 33 MHz }} | |||
{{Spec | Maximum Voltage | 500 V DC or AC peak }} | |||
{{Spec | Attenuation | ×10 ±3% with 1 MΩ scope input }} | |||
{{Spec | Compensation range | 15 to 47 pF }} | |||
{{Spec | Input capacitance | 11.5 pF w/3.5' cable, 14.5 pF w/6' cable, 17.5 pF w/9' cable }} | |||
{{EndSpecs}} | |||
==Manual== | ==Manual== | ||
Line 11: | Line 30: | ||
<gallery> | <gallery> | ||
Tek-p6012.png | Tek-p6012.png | ||
tektronix_P6012_compensation_box_1.jpg | |||
tektronix_P6012_compensation_box_2.jpg | |||
tektronix_P6012_compensation_box_3.jpg | |||
tektronix_P6012_part no..jpg | |||
tektronix_P6012_side_1.jpg | |||
tektronix_P6012_slip_on_tip.jpg | |||
Tektronix_P6012_derating_3.5 ft._cable.png | |||
</gallery> | </gallery> | ||
[[Category:1 MΩ Oscilloscope probes]] | [[Category:1 MΩ Oscilloscope probes]] | ||
Latest revision as of 01:04, 3 July 2023
The Tektronix P6012 is a passive 10× probe with 33 MHz bandwidth.
It comes with 3.5', 6', or 9' cable and a BNC connector. It has a small diameter probe body, making it more useful in crowded circuitry.
Key Specifications
Bandwidth | 33 MHz |
---|---|
Maximum Voltage | 500 V DC or AC peak |
Attenuation | ×10 ±3% with 1 MΩ scope input |
Compensation range | 15 to 47 pF |
Input capacitance | 11.5 pF w/3.5' cable, 14.5 pF w/6' cable, 17.5 pF w/9' cable |