TDS210: Difference between revisions

From TekWiki
Jump to navigation Jump to search
(Added Firmware v1.06)
(Added TDS200 recall document)
 
(7 intermediate revisions by 2 users not shown)
Line 12: Line 12:
* [[Media:061-4231-02.pdf|TDS200 Series Release Notes 061-4231-02]]
* [[Media:061-4231-02.pdf|TDS200 Series Release Notes 061-4231-02]]
* [[Media:063-2644-02.pdf|TDS200/1000/2000 Series Extension Module Installation Manual 063-2644-02]]
* [[Media:063-2644-02.pdf|TDS200/1000/2000 Series Extension Module Installation Manual 063-2644-02]]
* [[Media:070-9565-04.pdf|TDS200-Series Extension Modules Instruction Manual 070-9565-04]]
* [[Media:071-0398-03.pdf|TDS200 Series User Manual 071-0398-03]]
* [[Media:071-0398-03.pdf|TDS200 Series User Manual 071-0398-03]]
* [[Media:071-0409-01.pdf|TDS200 Extension Modules Manual 071-0409-01]]
* [[Media:071-0409-01.pdf|TDS200 Extension Modules Manual 071-0409-01]]
* [[Media:071-0492-03.pdf|TDS200 Series Service Manual 071-0492-03]]
* [[Media:071-0492-03.pdf|TDS200 Series Service Manual 071-0492-03]]
* [[Media:071-0493-01.pdf|TDS200 Series Programmers Manual 071-0493-01]]
* [[Media:071-0493-01.pdf|TDS200 Series Programmers Manual 071-0493-01]]
* [[Media:071-1075-03.pdf|TDS200/1000/2000 Series Programmer Manual 071-1075-03]]
* [[Media:071-1075-04.pdf|TDS200/1000/2000 Series Programmer Manual 071-1075-04]]
* [[Media:071-1075-04.pdf|TDS200/1000/2000 Series Programmer Manual 071-1075-04]]
* [[Media:071-1857-00.pdf|TDS200/1000/2000 Series Memory Erasure and Parts List Manual 017-1857-00]]
* [[Media:071-1857-00.pdf|TDS200/1000/2000 Series Memory Erasure and Parts List Manual 071-1857-00]]
* [[Media:077-0444-01.pdf|TDS200/1000/2000 Series Programmer Manual 077-0444-01]]
* [[Media:077-0444-01.pdf|TDS200/1000/2000 Series Programmer Manual 077-0444-01]]
* [[Media:SUP40-003c.pdf|TDS210/220 Service Update Plan 40-003c - Safety Recall Details]]
* Schematics needed
* Schematics needed
}}
}}
Line 35: Line 40:
* Automatic Measurements: Period, frequency, cycle RMS, mean, peak-to-peak
* Automatic Measurements: Period, frequency, cycle RMS, mean, peak-to-peak
* Acquisition Modes: Sample, Average, Peak Detect - High frequency and random glitch capture
* Acquisition Modes: Sample, Average, Peak Detect - High frequency and random glitch capture
* Waveform Storage: TDS210 and TDS220: Two 2,500 point reference waveforms, TDS224: Four 2,500 point reference waveforms
* Waveform Storage: Two 2,500 point reference waveforms
* Setups: 5 front panel setups
* Setups: 5 front panel setups
* Cursors (Voltage, time) - measure Delta T, 1/Delta T, Delta V
* Cursors (Voltage, time) - measure Delta T, 1/Delta T, Delta V
Line 42: Line 47:
* Backlit monochrome LCD with adjustable multilevel contrast
* Backlit monochrome LCD with adjustable multilevel contrast
* Persistence: Off, 1 sec, 2 sec, 5 sec, infinite
* Persistence: Off, 1 sec, 2 sec, 5 sec, infinite
* X-Y mode
* X-Y mode  
* Included [[P2100]] Passive probe
}}
}}
{{EndSpecs}}
{{EndSpecs}}


==Software==
==Software==
* [[Media:066-0002-00.zip|Waveform Converter For Oscilloscopes 066-0002-00]] (ZIP)
* [[Media:066-0104-00.zip|File Transfer Utility From TDS Scope To PC 066-0104-00]] (ZIP)
* [[Media:066-0106-00.zip|TDS200 series waveform transfer Mac as ASCII - 066-0106-00]] (ZIP)
* [[Media:066-0106-00.zip|TDS200 series waveform transfer Mac as ASCII - 066-0106-00]] (ZIP)
* [[Media:066-0108-00.zip|TDS200 series 2XX sample RS232 program - 066-0108-00]] (ZIP)
* [[Media:066-0108-00.zip|TDS200 series 2XX sample RS232 program - 066-0108-00]] (ZIP)
* [[Media:066-0109-00.zip|DOS program to display FFT - 066-0109-00]] (ZIP)
* [[Media:066-0109-00.zip|DOS program to display FFT - 066-0109-00]] (ZIP)
* [[Media:066-0176-00.zip|WFM to ASCII Waveform Converter - UNIX Version For Sun Spark Stations 066-0176-00]] (ZIP)
* [[Media:066-0177-00.zip|Hardcopy from TDS to PC Using HPIP 82335B Interface Card 066-0177-00]] (ZIP)
* [[Media:066-0178-00.zip|Example Program To Get Crossing Levels 066-0178-00]] (ZIP)
* [[Media:066-0179-00.zip|TDS ISF File To CSV File Conversion Utility 066-0179-00]] (ZIP)
* [[Media:066-0188-00.zip|Transfer 2 Byte Data From TDS Oscilloscopes QuickBasic 066-0188-00]] (ZIP)
* [[Media:066-0194-00.zip|TDS Waveform Logging Sample Program 066-0194-00]] (ZIP)
* [[Media:066-0196-00.zip|Load TDS Floppy MathCAD Files Into MathCAD 066-0196-00]] (ZIP)
* [[Media:066-0197-00.zip|Transfer TDS Hardcopy Screens To PC Via GPIB 066-0197-00]] (ZIP)
* [[Media:066-0198-00.zip|Transfer Setups Between TDS Oscilloscopes 066-0198-00]] (ZIP)
* [[Media:066-0200-00.zip|VB Program To Capture TDS Extended Waveforms 066-0200-00]] (ZIP)
* [[Media:066-0934-03.zip|Wavestar for Oscilloscopes V3.0.0 - 066-0934-03]] (ZIP) (105 Mb)
* [[Media:066-0934-03.zip|Wavestar for Oscilloscopes V3.0.0 - 066-0934-03]] (ZIP) (105 Mb)
* [[Media:066-0938-09.zip|TekVISA Connectivity Software V4.0.4 - 066-0938-09]] (ZIP) (447 Mb)
* [[Media:066-0938-09.zip|TekVISA Connectivity Software V4.0.4 - 066-0938-09]] (ZIP) (447 Mb)
Line 60: Line 76:
==Firmware==
==Firmware==
* [[Media:TDS210-220_v1.06_Firmware_163-0792-01.zip|TDS210-220 v1.06 Firmware - 163-0792-01]] (ZIP)
* [[Media:TDS210-220_v1.06_Firmware_163-0792-01.zip|TDS210-220 v1.06 Firmware - 163-0792-01]] (ZIP)
* [[Media:TDS210-220_v1.09_Firmware_163-0792-02.zip|TDS210-220 v1.09 Firmware - 163-0792-02]] (ZIP)
* [[Media:163-0792-03.zip|TDS210-220 v1.16 Firmware - 163-0792-03]] (ZIP)
* [[Media:163-0792-03.zip|TDS210-220 v1.16 Firmware - 163-0792-03]] (ZIP)
* [[Media:TDS210-220_v1.17_Firmware_163-0792-04.zip|TDS210-220 v1.17 Firmware - 163-0792-04]] (ZIP)
* [[Media:TDS210-220_v1.19_Firmware_163-0792-06.zip|TDS210-220 v1.19 Firmware - 163-0792-06]] (ZIP)
* [[Media:TDS210-220_v1.19_Firmware_163-0792-06.zip|TDS210-220 v1.19 Firmware - 163-0792-06]] (ZIP)


==Options==
==Options==
* [[TDS2HM]] Hard Copy module:
** Centronics parallel (printer)
* [[TDS2CM]], [[TDS2CMA]], [[TDS2CMAX]] Communications module:
* [[TDS2CM]], [[TDS2CMA]], [[TDS2CMAX]] Communications module:
** Centronics parallel (printer), RS-232 serial, GPIB
** Centronics parallel (printer), RS-232 serial, GPIB

Latest revision as of 06:05, 12 July 2023

Manuals – Specifications – Links – Pictures

The Tektronix TDS210 is a portable two-channel digital scope with 1 GS/s sampling rate and 60 MHz bandwidth.

Sister models include TDS220 (100 MHz dual-channel) and TDS224 (100 MHz quad-channel) .

Key Specifications

Bandwidth 60 MHz (20 MHz at 2 mV/Div and 5 mV/Div, 20 MHz at 10 mV/Div in Peak Detect mode)
Sampling rate 1 GS/s
Sweep 5 ns/Div to 5 s/Div
Record Length 2,500 sample points per channel
Deflection 2 mV/Div to 5 V/Div, 1-2-5
Resolution 8 bit (256 levels over 10.24 vertical divisions)
Features
  • Automatic Measurements: Period, frequency, cycle RMS, mean, peak-to-peak
  • Acquisition Modes: Sample, Average, Peak Detect - High frequency and random glitch capture
  • Waveform Storage: Two 2,500 point reference waveforms
  • Setups: 5 front panel setups
  • Cursors (Voltage, time) - measure Delta T, 1/Delta T, Delta V
  • Waveform Processing: Arithmetic Operators Add, subtract
  • Single button automatic setup on selected input signal for vertical, horizontal and trigger systems
  • Backlit monochrome LCD with adjustable multilevel contrast
  • Persistence: Off, 1 sec, 2 sec, 5 sec, infinite
  • X-Y mode

Software

Firmware

Options

  • TDS2HM Hard Copy module:
    • Centronics parallel (printer)
  • TDS2CM, TDS2CMA, TDS2CMAX Communications module:
    • Centronics parallel (printer), RS-232 serial, GPIB
  • TDS2MM Measurement Extension Module:
    • Functions of TDS2CM plus:
    • 2048-point FFT, with Hanning, Flat Top, Rectangular windows
    • Automatic Measurements - Rise/fall time, positive/negative pulse width

Optional Accessories

  • RM200 – Rack mount kit
  • AC220 – Soft case
  • HCTDS32 – Hard case

Links

Pictures