P5205: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
(5 intermediate revisions by the same user not shown) | |||
Line 9: | Line 9: | ||
|discontinued=(?) | |discontinued=(?) | ||
|manuals= | |manuals= | ||
* [[Media:070-9472- | * [[Media:070-9472-03.pdf|Tektronix P5205 Manual -03]] | ||
* [[Media:070-9472-02.pdf|Tektronix P5205 Manual -02]] | * [[Media:070-9472-02.pdf|Tektronix P5205 Manual -02]] | ||
* [[Media:P5205_Schematics.pdf|P5205 Schematics]] | * [[Media:P5205_Schematics.pdf|P5205 Schematics]] | ||
Line 16: | Line 16: | ||
}} | }} | ||
The '''Tektronix P5205''' is a high-voltage active differential probe with a [[Tekprobe BNC connector]]. | The '''Tektronix P5205''' is a high-voltage active differential probe with a [[Tekprobe BNC connector]]. | ||
The [[P5210]] is a 50 MHz ×100/×1000 sister model. | |||
{{BeginSpecs}} | {{BeginSpecs}} | ||
{{Spec | Bandwidth | 100 MHz }} | {{Spec | Bandwidth | 100 MHz (5 MHz limit switchable) }} | ||
{{Spec | Attenuation | 50:1 or 500:1 }} | |||
{{Spec | Maximum input | | |||
* 500×: ± 1.3 kV (DC + peak AC), ±1 kV<sub>RMS</sub> common mode | |||
* 50×: ± 130 V (DC + peak AC), ± 1kV<sub>RMS</sub> common mode | |||
}} | |||
{{Spec | Maximum nondestructive input | ±1.5 kV (DC + peak AC), ±1.3 kV<sub>RMS</sub> common mode }} | |||
{{Spec | CMRR | 80 dB @ 60 Hz, 50 dB @ 1 MHz }} | |||
{{Spec | Input impedance | 4 MΩ // 7 pF between each input and ground }} | |||
{{Spec | Output | 50 Ω output drives 1 MΩ // 15-20 pF scope input }} | |||
{{Spec | Features | | |||
* visible/audible overvoltage indicator | |||
}} | |||
{{EndSpecs}} | {{EndSpecs}} | ||
==Links== | |||
* [https://www.eevblog.com/forum/testgear/tek-p5205-hv-differeantial-probe-teardown-btw-what-are-the-red-and-brown-wires/ Tek P5205 HV differential probe teardown] @ EEVBLOG (with internal photos) | |||
==Pictures== | ==Pictures== | ||
Line 26: | Line 42: | ||
Tek p5205 kit.jpg | Tek p5205 kit.jpg | ||
Tek p5205.jpg | Tek p5205.jpg | ||
Tek P5205 board top.jpg | PCB, top view | |||
Tek P5205 board bottom.jpg | PCB, bottom view | |||
</gallery> | </gallery> | ||
Latest revision as of 09:41, 1 August 2023
The Tektronix P5205 is a high-voltage active differential probe with a Tekprobe BNC connector.
The P5210 is a 50 MHz ×100/×1000 sister model.
Key Specifications
Bandwidth | 100 MHz (5 MHz limit switchable) |
---|---|
Attenuation | 50:1 or 500:1 |
Maximum input |
|
Maximum nondestructive input | ±1.5 kV (DC + peak AC), ±1.3 kVRMS common mode |
CMRR | 80 dB @ 60 Hz, 50 dB @ 1 MHz |
Input impedance | 4 MΩ // 7 pF between each input and ground |
Output | 50 Ω output drives 1 MΩ // 15-20 pF scope input |
Features |
|
Links
- Tek P5205 HV differential probe teardown @ EEVBLOG (with internal photos)
Pictures
-
-
-
PCB, top view
-
PCB, bottom view