360: Difference between revisions

430 bytes added ,  21 September 2023
no edit summary
No edit summary
No edit summary
 
(13 intermediate revisions by 3 users not shown)
Line 1: Line 1:
{{Oscilloscope Sidebar |
{{Oscilloscope Sidebar  
title=Tektronix 360 |
|manufacturer=Tektronix
summary=CRT Indicator Unit |
|series=160
image=Tek 360 front.jpg |
|model=360  
caption=Tektronix 360 front view |
|summary=CRT Indicator Unit  
introduced=1954 |
|image=Tek 360 front.jpg  
discontinued=1973 |
|caption=Tektronix 360 front view  
manuals=
|introduced=1954  
* [http://bama.edebris.com/download/tek/160/tek%20160.pdf Tektronix 160 Series Manual (PDF)]
|discontinued=1973  
* [http://w140.com/tek_360_160_irb.pdf Tektronix 160-series Instrument Reference Book (PDF, OCR)]
|designers=
|manuals=
* [[Media:070-220.pdf|Tektronix 160 Series Manual]]
* [[Media:Tek_360_160_irb.pdf|Tektronix 160-series Instrument Reference Book]] (OCR, 210MB!)
* [[Media:Tek 360 fcp.pdf|Tektroni 360 Factory Calibration Procedure]] (OCR)
}}
}}
The '''Tektronix Type 360''' is the "indicator unit" of the [[160|160 series modular scope system]].
The '''Tektronix Type 360''' is the "indicator unit" of the [[160|160 series modular scope system]].
It contains a [[3WP]] CRT, vertical amplifier, horizontal amplifier, and
It contains a [[3WP]] CRT ([[T3100]] for SN > 25767), vertical amplifier, horizontal amplifier, and HV CRT circuit.   
HV CRT circuit.  It does not contain the low-voltage power supply, which is
It does not contain the low-voltage power supply, which is a separate component in the 160 system.   
a separate component in the 160 system.   


==Internals==
==Internals==
Line 32: Line 34:
voltage, and one for the CRT cathode voltage.  The high-voltage regulator
voltage, and one for the CRT cathode voltage.  The high-voltage regulator
feedback amplifier is made from two cascaded common-cathode amplifiers,
feedback amplifier is made from two cascaded common-cathode amplifiers,
each made from one half of a [[12AT7]] dual triode.
each made from one half of a [[12AT7]] dual triode.A high voltage
isolation transformer (1:1) is used to power the CRT filament from the
main 6.3V heater line.  


===Mechanical===
===Mechanical===
Open-frame construction allows the 360 to operate without fan cooling.
Open-frame construction allows the 360 to operate without fan cooling.
Some 360s are made using printed circuit boards.  Others are made
360s with SN < 1000 were made using printed circuit boards, later SN are made
using the ceramic wiring strip style that is more typical of 1950s
using the ceramic wiring strip style that is more typical of the 1950s
and 1960s Tektronix construction.
and 1960s Tektronix construction.


Line 44: Line 48:
<gallery>
<gallery>
Tek 360 front.jpg|360 front view
Tek 360 front.jpg|360 front view
Tek_360_Trace1.jpeg | 360 Trace
Tek 360 rear.jpg|The BNC connectors are a modification.
Tek 360 rear.jpg|The BNC connectors are a modification.
Tek 360 left.jpg
Tek 360 left.jpg
Tek 360 right.jpg
Tek 360 right.jpg
Tek_360-LHS.jpeg | LHS
Tek_360-LHS1.jpeg| LHS, HV Cover off
Tek_360-RHS.jpeg | RHS
Tek_360-RHS1.jpeg| RHS, HV Cover off
Tek_360-Top.jpeg | Top
Tek 360-amplifiers.png|Amplifiers schematic
Tek 360-amplifiers.png|Amplifiers schematic
Tek 360-crt circuit.png|CRT circuit
Tek 360-crt circuit.png|CRT circuit
</gallery>
</gallery>
==Components==
{{Parts|360}}


[[Category:160 system]]
[[Category:160 system]]