A6901: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
(One intermediate revision by the same user not shown)
Line 11: Line 11:
|designers=
|designers=
|manuals=
|manuals=
* [http://w140.com/tek_a6901.pdf Tektronix A6901 Manual (PDF)]
* [[Media:070-3618-00.pdf|Tektronix A6901 Manual]] (PDF)
}}
}}
The '''Tektronix A6901 Ground Isolation Monitor''' connects between mains power and test equipment without connecting protective ground, in order to safely allow referencing measurements to a low voltage instead of ground, or break ground loops.
The '''Tektronix A6901 Ground Isolation Monitor''' connects between mains power and test equipment without connecting protective ground, in order to safely allow referencing measurements to a low voltage instead of ground, or break ground loops.
Line 24: Line 24:
{{Spec|Load power|500 W max.}}
{{Spec|Load power|500 W max.}}
{{EndSpecs}}
{{EndSpecs}}
==Links==
{{Documents|Link=A6901}}


[[File:A6901 principle.jpg | thumb | 350px| Operating principle (click to enlarge)]]
[[File:A6901 principle.jpg | thumb | 350px| Operating principle (click to enlarge)]]


[[Category:Power supplies]]
[[Category:Power supplies]]

Latest revision as of 02:33, 10 October 2023

Tektronix A6901
Ground Isolation Monitor
Tektronix A6901 Ground Isolation Monitor

Produced from 1981 to (?)

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix A6901 Ground Isolation Monitor connects between mains power and test equipment without connecting protective ground, in order to safely allow referencing measurements to a low voltage instead of ground, or break ground loops.

It monitors the floating equipment ground voltage. If the voltage exceeds 40 V peak, or ground current exceeds a selectable limit of 0.5, 3.5 or 5 mA, the A6901 disconnects mains power and grounds the test equipment.

Key Specifications

DC trip voltage 28 VRMS (40 V peak) or ±40 V DC
Current trip ±0.5 mA, ±3.5 mA and ±5 mA max. selectable
Trip delay <200 ms
Line voltage 90-128 V; 180-250 V; 48-66 Hz
Load power 500 W max.

Links

Documents Referencing A6901

Document Class Title Authors Year Links
60AX-4741.pdf Application Note Floating Oscilloscope Measurements ... And Operator Protection 1981


Operating principle (click to enlarge)