The Tektronix 067-0680-00 is a plug-in used to calibrate a 5400-series mainframe's horizontal and vertical deflection factors and step response, and help align CRT geometry.
It provides a calibrated stair-step signal for deflection factor and geometry adjustment, a fast-risetime step function for checking and trimming step response, a leveling circuit for an external sinewave test signal, and a common-mode input test for both the vertical and trigger systems.
It is similar to the 067-0587-xx for 7000 series scopes.
Key Specifications
- please add