S-50: Difference between revisions

36 bytes removed ,  10 December 2023
no edit summary
(→‎Specifications: std table class)
No edit summary
 
(7 intermediate revisions by 2 users not shown)
Line 1: Line 1:
{{Plugin Sidebar 2|
{{Plugin Sidebar
title=Tektronix S-50 |
|manufacturer=Tektronix
summary=Pulse Generator |
|series=7000 and 3S series sampling heads
image=Tek s-50 front.jpg |
|type=S-50  
caption=S-50 Head |
|summary=Pulse Generator  
series=[[:Category:Sampling plugins|7000/S3 series Sampling Plugins]] |
|image=Tek s-50 front.jpg  
introduced=1969 |
|caption=S-50 Head  
discontinued=(?) |
|introduced=1969  
manuals=
|discontinued=1975 
* [http://w140.com/tek_s-50.pdf Tektronix S-50 Manual (46MB, PDF)]
|designers=
* [http://w140.com/tek_s-series_sampling_heads.pdf Tektronix S-Series Sampling Heads (195MB, PDF)]
|manuals=
* [[Media:070-0897-00.pdf|Tektronix S-50 Manual]]
}}
}}
 
The '''Tektronix S-50''' is a pulse generator head that produces 400 mV pulses with a rise time under 25 ps.   
The '''Tektronix S-50''' is a pulse generator head that produces 400 mV pulses with a rise time under 25 ps.  The pulse output is an  
The pulse output is an [[SMA connector]].  The PRETRIG OUT and TRIG OUT signals use [[BSM connector]]s.
[[Connectors#SMA|SMA connector]].  The PRETRIG OUT and TRIG OUT signals use [[Connectors #BSM|BSM connectors]].


The output diode is the same one that the [[S-52]] uses, the [[153-0040-00]].
The output diode is the same one that the [[S-52]] uses, the [[153-0040-00]].
Line 22: Line 22:
The S-50's output tunnel diode is directly connected to the main pulse output connector.   
The S-50's output tunnel diode is directly connected to the main pulse output connector.   
The S-52 has a 48-ohm resistor between the output tunnel diode and the main pulse output connector, resulting in a 2:1 voltage divider.   
The S-52 has a 48-ohm resistor between the output tunnel diode and the main pulse output connector, resulting in a 2:1 voltage divider.   
Another difference between the S-50 and S-52 is the presence of a TRIG OUT on the front of the of S-50. Both have PRETRIGGER OUT connectors.   
Another difference between the S-50 and S-52 is the presence of a TRIG OUT on the front of the of S-50.
Both have PRETRIGGER OUT connectors.   
The pretrigger of the S-50 leads the main pulse by 75 ns, that of the S-52 by 85 ns.   
The pretrigger of the S-50 leads the main pulse by 75 ns, that of the S-52 by 85 ns.   


At the circuit level, the S-50 and S-52 differ significantly. Both use a current switch to bias the output tunnel diode when
At the circuit level, the S-50 and S-52 differ significantly.
it is in the "armed" state.  The S-50 uses another tunnel diode to add a short pulse of current that "fires" the output tunnel diode. The S-52 uses a [[snap-off diode]] to generate this firing pulse.   
Both use a current switch to bias the output tunnel diode when it is in the "armed" state.   
The S-50 uses another tunnel diode to add a short pulse of current that "fires" the output tunnel diode.
The S-52 uses a [[snap-off diode]] to generate this firing pulse.   


Sequencing of events (arming the output diode, firing it, resetting it) is controlled by analog timing circuits in the S-50. The S-52 uses a digital counter and a decoder to generate the internal control signals.
Sequencing of events (arming the output diode, firing it, resetting it) is controlled by analog timing circuits in the S-50.
The S-52 uses a digital counter and a decoder to generate the internal control signals.


==Specifications==
==Specifications==
Line 77: Line 81:


<gallery>
<gallery>
File:Tek s-50 block.png|block diagram
Tek s-50 block.png|block diagram
Image:S-50 schem.png|schematic
S-50 schem.png|schematic
Image:Tek s-50.JPG|front view
Tek s-50.JPG|front view
Tek s-50 20203 1.jpg
Tek s-50 20203 2.jpg
Tek s-50 left internal.jpg|left internal view
Tek s-50 right internal.jpg|right internal view
</gallery>
</gallery>


[[Category:7000 and 3S series sampling heads]]
[[Category:7000 and 3S series sampling heads]]