P6008: Difference between revisions
(Deleted old "dead" link, corrected temperature ratings, minor additions to descriptions) |
No edit summary |
||
(6 intermediate revisions by 4 users not shown) | |||
Line 3: | Line 3: | ||
|model=P6008 | |model=P6008 | ||
|summary=Passive 66 MHz, x10 probe | |summary=Passive 66 MHz, x10 probe | ||
|image=Tek | |image=Tek P6008 early version.jpg | ||
|caption=Early P6008 | |caption=Early P6008 | ||
|for=1 MΩ scope inputs | |for=1 MΩ scope inputs | ||
Line 10: | Line 10: | ||
|designers= | |designers= | ||
|manuals= | |manuals= | ||
* [[Media:070-0362-01.pdf|Tektronix P6008 Manual, 1963 ( | * [[Media:070-0362-01.pdf|Tektronix P6008 Manual, 1963]] (OCR) | ||
* [[Media:070-1173-00.pdf|Tektronix P6008 | * [[Media:070-1173-00.pdf|Tektronix P6008 Environmental Probe Manual, 1971]] | ||
}} | }} | ||
There are two different versions, or generations, of the '''Tektronix P6008''' ×10 passive voltage probe. | There are two different versions, or generations, of the '''Tektronix P6008''' ×10 passive voltage probe. | ||
Line 19: | Line 19: | ||
The '''early (1963) P6008 Probe (010-130 & 010-0130-00)''' was primarily designed for use with the [[82|Type 82]] and [[86|Type 86]] plug-ins in a [[580-series_scopes|580-series scope]], with 15 pF inputs. | The '''early (1963) P6008 Probe (010-130 & 010-0130-00)''' was primarily designed for use with the [[82|Type 82]] and [[86|Type 86]] plug-ins in a [[580-series_scopes|580-series scope]], with 15 pF inputs. | ||
It came with a 3.5 foot gray cable. | It came with a 3.5 foot gray cable. | ||
Like the other members of the monolithic probe family, the early P6008 was rated for temperatures up to | Like the other members of the [[6-32_probes|monolithic probe family]], the early P6008 was rated for temperatures up to 75 °C. | ||
{{BeginSpecs}} | {{BeginSpecs}} | ||
{{Spec | Attenuation | 10 × ±3% with 1 MΩ ±2% scope input }} | {{Spec | Attenuation | 10 × ±3% with 1 MΩ ±2% scope input }} | ||
{{Spec | Maximum Voltage | 600 V DC or AC p-p, derated above 20 MHz }} | |||
{{Spec | Compensation range | 15 pF (may be compensated to 20 pF with some loss of bandwidth) }} | {{Spec | Compensation range | 15 pF (may be compensated to 20 pF with some loss of bandwidth) }} | ||
{{Spec | Bandwidth | 66 MHz w/Type 82 or 86 Plugin (63 MHz with x10 GAIN) }} | {{Spec | Bandwidth | 66 MHz w/Type 82 or 86 Plugin (63 MHz with x10 GAIN) }} | ||
{{Spec | Input capacitance | ~7 pF }} | {{Spec | Input capacitance | ~7 pF }} | ||
{{EndSpecs}} | {{EndSpecs}} | ||
Line 31: | Line 32: | ||
The '''later (1971) P6008 ENVIRONMENTAL PROBE (010-0130-01)''' can be compensated to a wider range of scope input capacitances, has wider bandwidth, but higher input capacitance. | The '''later (1971) P6008 ENVIRONMENTAL PROBE (010-0130-01)''' can be compensated to a wider range of scope input capacitances, has wider bandwidth, but higher input capacitance. | ||
It came with a 6 foot white cable. | It came with a 6 foot white cable. | ||
This later version of the P6008 was rated for temperatures up to | This later version of the P6008 was rated for temperatures up to 150 °C for the probe and cable and up to 55 °C for the compensation box. | ||
{{BeginSpecs}} | {{BeginSpecs}} | ||
{{Spec | Attenuation | 10 × ±3% with | {{Spec | Attenuation | 10 × ±3% with 1 MΩ ±2% scope input }} | ||
{{Spec | Maximum Voltage | 600 V, DC + peak AC, derated with frequency }} | |||
{{Spec | Compensation range | 15 pF to 55 pF }} | {{Spec | Compensation range | 15 pF to 55 pF }} | ||
{{Spec | Bandwidth | 100 MHz w/15 pF scope inputs }} | {{Spec | Bandwidth | 100 MHz w/15 pF scope inputs }} | ||
{{Spec | Input capacitance | 10-14 pF, depending on scope input capacitance }} | {{Spec | Input capacitance | 10-14 pF, depending on scope input capacitance }} | ||
{{EndSpecs}} | {{EndSpecs}} | ||
==Pictures== | ==Pictures== | ||
'''Early P6008''' | |||
<gallery> | |||
Tek P6008 early version.jpg | | |||
Tek p6008 1.JPG | | |||
P6008_Int-1.jpeg | Compensating Box Internals | |||
</gallery> | |||
'''1971 version''' | |||
<gallery> | <gallery> | ||
</gallery> | </gallery> | ||
''please add photos'' | |||
[[Category:1 MΩ Oscilloscope probes]] | [[Category:1 MΩ Oscilloscope probes]] | ||
[[Category:6-32 probes]] |
Latest revision as of 01:56, 10 March 2024
There are two different versions, or generations, of the Tektronix P6008 ×10 passive voltage probe. Each was fitted with a BNC connector with no readout encoding pin.
010-0130-00
The early (1963) P6008 Probe (010-130 & 010-0130-00) was primarily designed for use with the Type 82 and Type 86 plug-ins in a 580-series scope, with 15 pF inputs. It came with a 3.5 foot gray cable. Like the other members of the monolithic probe family, the early P6008 was rated for temperatures up to 75 °C.
Key Specifications
Attenuation | 10 × ±3% with 1 MΩ ±2% scope input |
---|---|
Maximum Voltage | 600 V DC or AC p-p, derated above 20 MHz |
Compensation range | 15 pF (may be compensated to 20 pF with some loss of bandwidth) |
Bandwidth | 66 MHz w/Type 82 or 86 Plugin (63 MHz with x10 GAIN) |
Input capacitance | ~7 pF |
010-0130-01
The later (1971) P6008 ENVIRONMENTAL PROBE (010-0130-01) can be compensated to a wider range of scope input capacitances, has wider bandwidth, but higher input capacitance. It came with a 6 foot white cable. This later version of the P6008 was rated for temperatures up to 150 °C for the probe and cable and up to 55 °C for the compensation box.
Key Specifications
Attenuation | 10 × ±3% with 1 MΩ ±2% scope input |
---|---|
Maximum Voltage | 600 V, DC + peak AC, derated with frequency |
Compensation range | 15 pF to 55 pF |
Bandwidth | 100 MHz w/15 pF scope inputs |
Input capacitance | 10-14 pF, depending on scope input capacitance |
Pictures
Early P6008
-
-
-
Compensating Box Internals
1971 version
please add photos