P6008: Difference between revisions

From TekWiki
Jump to navigation Jump to search
(Deleted old "dead" link, corrected temperature ratings, minor additions to descriptions)
No edit summary
 
(6 intermediate revisions by 4 users not shown)
Line 3: Line 3:
|model=P6008
|model=P6008
|summary=Passive 66 MHz, x10 probe
|summary=Passive 66 MHz, x10 probe
|image=Tek p6008 1.JPG
|image=Tek P6008 early version.jpg
|caption=Early P6008
|caption=Early P6008
|for=1 MΩ scope inputs
|for=1 MΩ scope inputs
Line 10: Line 10:
|designers=
|designers=
|manuals=
|manuals=
* [[Media:070-0362-01.pdf|Tektronix P6008 Manual, 1963 (PDF, needs OCR)]]
* [[Media:070-0362-01.pdf|Tektronix P6008 Manual, 1963]] (OCR)
* [[Media:070-1173-00.pdf|Tektronix P6008 ENVIRONMENTAL PROBE Manual, 1971 (PDF)]]
* [[Media:070-1173-00.pdf|Tektronix P6008 Environmental Probe Manual, 1971]]
}}
}}
There are two different versions, or generations, of the '''Tektronix P6008''' ×10 passive voltage probe.
There are two different versions, or generations, of the '''Tektronix P6008''' ×10 passive voltage probe.
Line 19: Line 19:
The '''early (1963) P6008 Probe (010-130 & 010-0130-00)''' was primarily designed for use with the [[82|Type 82]] and [[86|Type 86]] plug-ins in a [[580-series_scopes|580-series scope]], with 15 pF inputs.
The '''early (1963) P6008 Probe (010-130 & 010-0130-00)''' was primarily designed for use with the [[82|Type 82]] and [[86|Type 86]] plug-ins in a [[580-series_scopes|580-series scope]], with 15 pF inputs.
It came with a 3.5 foot gray cable.
It came with a 3.5 foot gray cable.
Like the other members of the monolithic probe family, the early P6008 was rated for temperatures up to 75 C.
Like the other members of the [[6-32_probes|monolithic probe family]], the early P6008 was rated for temperatures up to 75 °C.


{{BeginSpecs}}
{{BeginSpecs}}
{{Spec | Attenuation | 10 × ±3% with 1 MΩ ±2% scope input }}
{{Spec | Attenuation | 10 × ±3% with 1 MΩ ±2% scope input }}
{{Spec | Maximum Voltage | 600 V DC or AC p-p, derated above 20 MHz }}
{{Spec | Compensation range | 15 pF (may be compensated to 20 pF with some loss of bandwidth) }}
{{Spec | Compensation range | 15 pF (may be compensated to 20 pF with some loss of bandwidth) }}
{{Spec | Bandwidth | 66 MHz w/Type 82 or 86 Plugin (63 MHz with x10 GAIN) }}
{{Spec | Bandwidth | 66 MHz w/Type 82 or 86 Plugin (63 MHz with x10 GAIN) }}
{{Spec | Input capacitance | ~7 pF }}  
{{Spec | Input capacitance | ~7 pF }}
{{EndSpecs}}
{{EndSpecs}}


Line 31: Line 32:
The '''later (1971) P6008 ENVIRONMENTAL PROBE (010-0130-01)''' can be compensated to a wider range of scope input capacitances, has wider bandwidth, but higher input capacitance.
The '''later (1971) P6008 ENVIRONMENTAL PROBE (010-0130-01)''' can be compensated to a wider range of scope input capacitances, has wider bandwidth, but higher input capacitance.
It came with a 6 foot white cable.
It came with a 6 foot white cable.
This later version of the P6008 was rated for temperatures up to 150 C for the probe and cable and up to 55 C for the compensation box.
This later version of the P6008 was rated for temperatures up to 150 °C for the probe and cable and up to 55 °C for the compensation box.


{{BeginSpecs}}
{{BeginSpecs}}
{{Spec | Attenuation | 10 × ±3% with scope input at 1 MΩ ±2% }}
{{Spec | Attenuation | 10 × ±3% with 1 MΩ ±2% scope input }}
{{Spec | Maximum Voltage | 600 V, DC + peak AC, derated with frequency }}
{{Spec | Compensation range | 15 pF to 55 pF }}
{{Spec | Compensation range | 15 pF to 55 pF }}
{{Spec | Bandwidth | 100 MHz w/15 pF scope inputs }}
{{Spec | Bandwidth | 100 MHz w/15 pF scope inputs }}
{{Spec | Input capacitance | 10-14 pF, depending on scope input capacitance  }}  
{{Spec | Input capacitance | 10-14 pF, depending on scope input capacitance  }}
{{EndSpecs}}  
{{EndSpecs}}


==Pictures==
==Pictures==
'''Early P6008'''
<gallery>
Tek P6008 early version.jpg |
Tek p6008 1.JPG            |
P6008_Int-1.jpeg            | Compensating Box Internals
</gallery>
'''1971 version'''
<gallery>
<gallery>
Tek p6008 1.JPG | Early P6008 Probe
P6008_Int-1.jpeg | Early Compensating Box Internals
</gallery>
</gallery>
''please add photos''


[[Category:1 MΩ Oscilloscope probes]]
[[Category:1 MΩ Oscilloscope probes]]
[[Category:6-32 probes]]

Latest revision as of 01:56, 10 March 2024

Tektronix P6008
Passive 66 MHz, x10 probe
Early P6008

Compatible with 1 MΩ scope inputs

Produced from (?) to (?)

Manuals


Manuals – Specifications – Links – Pictures

There are two different versions, or generations, of the Tektronix P6008 ×10 passive voltage probe. Each was fitted with a BNC connector with no readout encoding pin.

010-0130-00

The early (1963) P6008 Probe (010-130 & 010-0130-00) was primarily designed for use with the Type 82 and Type 86 plug-ins in a 580-series scope, with 15 pF inputs. It came with a 3.5 foot gray cable. Like the other members of the monolithic probe family, the early P6008 was rated for temperatures up to 75 °C.

Key Specifications

Attenuation 10 × ±3% with 1 MΩ ±2% scope input
Maximum Voltage 600 V DC or AC p-p, derated above 20 MHz
Compensation range 15 pF (may be compensated to 20 pF with some loss of bandwidth)
Bandwidth 66 MHz w/Type 82 or 86 Plugin (63 MHz with x10 GAIN)
Input capacitance ~7 pF

010-0130-01

The later (1971) P6008 ENVIRONMENTAL PROBE (010-0130-01) can be compensated to a wider range of scope input capacitances, has wider bandwidth, but higher input capacitance. It came with a 6 foot white cable. This later version of the P6008 was rated for temperatures up to 150 °C for the probe and cable and up to 55 °C for the compensation box.

Key Specifications

Attenuation 10 × ±3% with 1 MΩ ±2% scope input
Maximum Voltage 600 V, DC + peak AC, derated with frequency
Compensation range 15 pF to 55 pF
Bandwidth 100 MHz w/15 pF scope inputs
Input capacitance 10-14 pF, depending on scope input capacitance

Pictures

Early P6008

1971 version

please add photos