T5191: Difference between revisions
No edit summary |
No edit summary |
||
(3 intermediate revisions by 2 users not shown) | |||
Line 25: | Line 25: | ||
==Datasheets and Links== | ==Datasheets and Links== | ||
* [[Media:T591_crt_data_tent.pdf|Tektronix T519 CRT Data, tentative]] ( | * [[Media:T591_crt_data_tent.pdf|Tektronix T519 CRT Data, tentative]] (OCR) | ||
* [[Media:T5910_crt_data.pdf|Tektronix T5190 CRT Data ( | * [[Media:T5910_crt_data.pdf|Tektronix T5190 CRT Data (OCR)]] | ||
* [[Media:T519P_REV_B.pdf|Tektronix T519 CRT Data, Rev B ( | * [[Media:T519P_REV_B.pdf|Tektronix T519 CRT Data, Rev B (OCR)]] | ||
* [[Media:Tek T5191 CRT Data Rev C.pdf|Tektronix T5191 CRT Data, Rev C ( | * [[Media:Tek T5191 CRT Data Rev C.pdf|Tektronix T5191 CRT Data, Rev C (OCR)]] | ||
* [[Patent US 2922074A]] | * [[Patent US 2922074A]] | ||
* https://vintagetek.org/519-1-ghz-oscilloscope/ | * https://vintagetek.org/519-1-ghz-oscilloscope/ | ||
* [[Patent US 3174070A]], Cliff Moulton, Electron beam deflection structure with compensation for beam transit time (f. 1961-08-14, g. 1965-03-16) | |||
==Pictures== | ==Pictures== | ||
Line 40: | Line 40: | ||
519 defl drawing.gif | deflection system | 519 defl drawing.gif | deflection system | ||
519 crt defl.jpg | deflection trimmers | 519 crt defl.jpg | deflection trimmers | ||
Tek t519 trimmers.jpg| trimmers | |||
Timkoeth 519 TWK 6448.jpg | screen mask with tube parameters | Timkoeth 519 TWK 6448.jpg | screen mask with tube parameters | ||
Tek 519 crt deflection1.jpg | Tek 519 crt deflection1.jpg |
Latest revision as of 12:48, 10 March 2024
The Tektronix T519 aka T5190, T5191, T5192 (P/N 154-0356-00, 154-0308-00) is a 1 GHz CRT for the 519 scope.
The usable screen area was 6 × 2 divisions. Total accelerating voltage in the 519 was 24 kV.
The tube has 125 Ω GR-874 connectors for signal and termination connections to the distributed vertical deflection plates that consist of S-shaped striplines. These were individually tuned for optimum response on a time-domain reflectometer before the deflection system was inserted into the tube during manufacturing.
Each tube was individually characterized for rise time and deflection sensitivity. The precise values (on the order of 350 ps and 10 V/Div, respectively) were written on the CRT and on the CRT bezel. The spot side of the T5191 CRT is unusually small (0.1 mm).
The T5192 is a special variant with bandwidth of 3 GHz.
The 1966 catalog lists the price of a 154-0308-00 replacement CRT as $1,000 (~$8,400 in 2021 dollars).
Part numbers
- T519 / T5190: 154-356 / 154-0356-00 (519 serial numbers 1016 and below)
- T5191: 154-308 / 154-0308-00 (519 serial numbers 1017 and up)
Datasheets and Links
- Tektronix T519 CRT Data, tentative (OCR)
- Tektronix T5190 CRT Data (OCR)
- Tektronix T519 CRT Data, Rev B (OCR)
- Tektronix T5191 CRT Data, Rev C (OCR)
- Patent US 2922074A
- https://vintagetek.org/519-1-ghz-oscilloscope/
- Patent US 3174070A, Cliff Moulton, Electron beam deflection structure with compensation for beam transit time (f. 1961-08-14, g. 1965-03-16)
Pictures
-
-
-
-
deflection system
-
deflection trimmers
-
trimmers
-
screen mask with tube parameters
-
-
-
-
-
-