{{Probe Sidebar | |||
|manufacturer=Tektronix | |||
|model=P6056 | |||
|summary=3.50 GHz passive probe | |||
|image=P6056.jpg | |||
|caption=P6056 probe | |||
|for=50 Ω scope inputs | |||
|introduced=1972 | |||
|discontinued=(?) | |||
|manuals= | |||
* [[Media:010-6056-03.pdf|Tektronix P6056/P6057 Manual]] | |||
}} | |||
The '''Tektronix P6056''' is a 3.5 GHz ×10 probe for 50 Ω-input scopes, released along with the [[7A19]] amplifier in 1972. | The '''Tektronix P6056''' is a 3.5 GHz ×10 probe for 50 Ω-input scopes, released along with the [[7A19]] amplifier in 1972. | ||
It has an Identify switch and readout | It has an Identify switch and [[readout encoding pin]]. | ||
Its sister model [[P6057]] has ×100 attenuation. | Its sister model [[P6057]] has ×100 attenuation. | ||
< | {{BeginSpecs}} | ||
{{Spec | Bandwidth | DC to 3.5 GHz }} | |||
{{Spec | Rise time | 100 ps }} | |||
{{Spec | Attenuation | 10× }} | |||
{{Spec | Input impedance | 500 Ω // approx. 1 pF }} | |||
{{Spec | Scope input impedance| 50 Ω }} | |||
{{Spec | Maximum input Voltage| 16 V DC or RMS }} | |||
{{Spec | Features | Readout Pin, ID Button }} | |||
{{EndSpecs}} | |||
<blockquote> | |||
<u>WARNING</u>: | |||
This high performance device has a fragile resistor assembly in the probe head, subject to failure in rough usage.<br /> | |||
Use with slip-on tip whenever possible. One replacement part is provided with the package.<br /> | |||
Contact nearest Field Office for additional parts (P/N 307-0330-00), if required.<br /> | |||
For replacement and Calibration Procedure, refer to Pg. 3 & 4 of manual.<br /> | |||
</blockquote> | |||
</ | |||
==Pictures== | |||
<gallery> | |||
P6056.jpg | |||
</gallery> | |||
[[Category:50 | [[Category:50 Ω Oscilloscope probes]] | ||
Latest revision as of 08:51, 25 March 2024
The Tektronix P6056 is a 3.5 GHz ×10 probe for 50 Ω-input scopes, released along with the 7A19 amplifier in 1972.
It has an Identify switch and readout encoding pin.
Its sister model P6057 has ×100 attenuation.
Key Specifications
Bandwidth | DC to 3.5 GHz |
---|---|
Rise time | 100 ps |
Attenuation | 10× |
Input impedance | 500 Ω // approx. 1 pF |
Scope input impedance | 50 Ω |
Maximum input Voltage | 16 V DC or RMS |
Features | Readout Pin, ID Button |
WARNING:
This high performance device has a fragile resistor assembly in the probe head, subject to failure in rough usage.
Use with slip-on tip whenever possible. One replacement part is provided with the package.
Contact nearest Field Office for additional parts (P/N 307-0330-00), if required.
For replacement and Calibration Procedure, refer to Pg. 3 & 4 of manual.